跳至主要内容
临床试验/NCT05812456
NCT05812456已完成不适用

Comparison of Shear Bond Strength of Different Commercial Brands of Stainless Steel Orthodontic Brackets: An in Vitro Study

Future University in Egypt1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2020年12月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
40
试验地点
1
主要终点
Estimation of Shear Bond Strength

研究概览

简要总结

some orthodontic brands are more expensive than others, one of the primary outcomes of this study is to know if is it worth using expensive brands? will it provide better quality treatment, in particular, bond strength? The treatment duration is long therefore it is expensive, either for the orthodontist and/or the patient.

This study will be comparing the bond strength of different commercial brands of stainless steel brackets.

详细描述

There are a plethora of studies in the science of orthodontics discussing different massive advances in the orthodontic adhesion concepts that allowed orthodontists to successfully bond brackets and tubes to teeth. the bond strength between the bracket and tooth should be sufficient to withstand the forces of mastication and the aggressive conditions of the oral environment. a commonly encountered problem is the failure of the bond between the bracket and tooth during treatment.

There are a lot of orthodontic in vitro studies that discussed bond failure and strength. multiple studies have studied the bracket-enamel bond strength with different curing systems and found that there was no significant difference in terms of bond strength. Several other studies discussed the effect of different adhesive systems on the bond strength to the enamel.

There are many studies that debated the shear bond strength of different metal bracket base shapes and sizes concluding that no differences in SBS for the surface area within the range of 6.82-12.35mm2 as well as the shape of the bracket base had no effect on shear bond strength.

The effectiveness or the success of the orthodontic treatment is arbitrated by achieving better aesthetics, better function, and better judgment for the patient too.

Even if there was a plethora of studies comparing the bond strength of different bracket shapes and sizes and also between metal and ceramic brackets, however, none have considered comparing shear bond strength of different bracket brands to enamel, Considering its cost and repeated failure which has its implication on both patient and orthodontist.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Other
盲法
Double (Investigator, Outcomes Assessor)

盲法说明

this is a double-blinded study (investigator-outcome assessor) this is a double-blinded study, for both the investigator and outcome assessor, as the investigator will be responsible for collecting the sample and preparing the sample for the experiment.

The outcome assessors will be blinded during the intervention application. as he/she will be responsible for analyzing the results of each group in the experiment.

入排标准

性别
All
接受健康志愿者

入选标准

  • sound extracted upper and/or lower permanent premolars.
  • Intact buccal enamel surface with n erosion and cracks.
  • the teeth must be free from caries, restoration, white spot lesions, or any sign of decalcification.
  • No pretreatment with any chemical agents such as hydrogen peroxide or formalin.

排除标准

  • teeth with amelogenesis or dentinogenesis imperfecta.
  • labially restored teeth.
  • endodontically treated teeth.
  • teeth with fluorosis.

结局指标

主要结局

Estimation of Shear Bond Strength

时间窗: 24 hours

Measuring shear bond strength between the different bracket brands and the enamel will be estimated by aiming the edge of the blade of the universal testing machine at bracket-enamel interface. The force required to debond each bracket will be registered in Newtons (N), and converted to Megapascals by dividing the force registered in newtons on each bracket base area (mm2).

次要结局

  • Evaluation of Adhesive Remanent Index(24 hours)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mostafa Hamdy Mohamed Afifi

Principle investigator

Future University in Egypt

研究点 (1)

Loading locations...

相似试验

Comparison Between Shear Bond Strength of Different... | 临床试验