Efficacy of a Low-cost Warming Mattress Celsi Warmer for the Management of Hypothermic Newborns at Muhimbili National Hospital, Dar es Salaam, Tanzania
- Conditions
- Neonatal Hypothermia
- Interventions
- Device: Celsi Warmer Mattress
- Registration Number
- NCT05876884
- Lead Sponsor
- William Marsh Rice University
- Brief Summary
The prevalence of hypothermia across low-resource settings is high, especially in countries with high neonatal mortality rates. If left untreated, hypothermia can additionally result in a significant comorbidity, and has been linked to a reduction in the effectiveness of treatment for other newborn conditions. Thermal care for hypothermic newborns is not widely available in low-resource settings due to cost, and lack of consumables and spare parts. In this study, the research team will evaluate the efficacy of a novel neonatal warming mattress intreating hypothermic newborns. The warming mattress, 'Celsi Warmer', has been developed by Rice360 Institute for Global Health Technologies, in conjunction with African clinicians, to be a robust, low-cost, and easy-to-use warming mattress which can address the challenges of hypothermia. This is a single-arm, non-randomized, prospective intervention study. Up to90eligible infants at Muhimbili National Hospital (MNH) at Upanga Neonatal Unit will be recruited to evaluate the efficacy of Celsi Warmer in rewarming hypothermic newborns. Infants temperature will be monitored during thermal intervention and the performance of the device will be evaluated. The temperatures of each infant will be compared before, during, and after the intervention.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- RECRUITING
- Sex
- All
- Target Recruitment
- 90
Any neonate who:
- Is currently being treated at study location
- Is an inborn admission to the neonatal ward
- Whose parents or guardians provided a written informed consent
- Whose parents or guardians providing informed consent are 18 years old or older
- Has a current weight of greater than or equal to 1.0 kg and less than or equal to 4.0kg
- Has been identified as in need of thermal care defined as having a moderate hypothermic temperature (32.0-36.0°C) as the last temperature recorded in hospital chart, or during recruitment procedures; and
- Is unable to be enrolled in Kangaroo Mother Care (KMC) for reasons including, but not limited to: a.Mother/guardian unable or unavailable to provide KMC b.Under observation in NICU before transfer to KMC c.No space in KMC d.Clinician's discretion
- May be receiving other medical treatments, including but not limited to, CPAP, oxygen therapy, IV fluids, management and monitoring of common newborn conditions such as hypoglycemia, and/or hyperbilirubinemia via LED phototherapy
The study will not interfere with any other treatment being provided at the ward, and it will not delay the participant from transferring to KMC or being discharged
Any neonate who:
- Requires mechanical ventilation
- Is deemed in need of intensive care by the hospital staff who is providing care,including but not limited to: a.neonates with severe anemia and/or any suspected hematological disorders, and/or b. Neonates with obvious congenital anomalies, and/or c.neonates suspected with hypo/hyperthyroidism or any hormonal disorders
- Has been diagnosed with birth asphyxia
- Presents a condition that precludes the use of the temperature sensor and/or abdominal belt including but not limited to, gastroschisis, known umbilical cord infection, known skin infection
- Whose clinician presents concerns about their participation
- Is receiving treatment that participation in the study would interfere with, i.e.transferring to KMC
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Hypothermic Neonates (90) Celsi Warmer Mattress Any neonate who been identified as in need of thermal care defined as having a moderate hypothermic temperature (32.0 - 36.0°C) as the last temperature recorded in hospital chart, or during recruitment procedures will be placed on the Celsi Warmer mattress
- Primary Outcome Measures
Name Time Method Broad Objective 1 year To evaluate the clinical efficacy and safety of the Celsi Warmer in rewarming hypothermic newborns by comparing the Celsi Warmer's accuracy in measuring neonatal temperature compared to the gold standard, axillary temperature readings.
- Secondary Outcome Measures
Name Time Method Efficacy of the Device 1 year To assess the performance of the Celsi Warmer in rewarming hypothermic newborns by measuring the incidence of attainment of normothermia (36.5-37.5°C)
Safety of Device 1 year To report any incidence of rebound hypothermia ( \< 36.5°C) (post-intervention hypothermia) up to 72 hours from the initial encounter
Trial Locations
- Locations (1)
Muhimbili National Hospital
🇹🇿Dar Es Salaam, Tanzania