Brief Summary

This study aims to compare the accuracy of measurement between ultrasonography and Cole formula in predicting uncuffed endotracheal tube diameter.

Detailed Description

Approval from Ethical Committee of Faculty of Medicine Universitas Indonesia was acquired prior conducting the study. Subjects were given informed consent before enrolling the study. Non-invasive blood pressure (NIBP) monitor, ECG and pulse-oximeter was set on the subjects in the operation room. The uncuffed endotracheal tube (ETT) diameter predictions were measured firstly using ultrasonography (USG), then with Cole formula. After that, polyvinyl chloride (Mallinckrodt) ETT intubation with Cole diameter measurement was inserted using direct laryngoscopy. If the ETT was too small, use a 0.5 mm bigger ETT than the prediction diameter, if it too big, use a 0.5 mm smaller ETT than the prediction diameter. Reintubation and measurements using both methods were recorded. If bradycardia or desaturation happened, positive pressure ventilation, 100% oxygen, atropine 0,01-0,02 mg/kg, adrenaline 0,01 mg/kg could be given. Data was analyzed using SPSS using Bivariat Chi-square test or Fisher Exact Test (categorical comparative analytical study).

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Subjects aged 1-6 years old, Malayan race, planned to undergo elective surgery with general anesthesia with intubation
  • Subjects with ASA status I-II
  • Cooperative subjects
  • Subjects whose parents had signed the informed consent
Exclusion Criteria
  • Subjects with allergies to Ultrasonography jelly
  • Subjects with difficult airway
  • Subjects with mass in the neck area
  • Subjects with respiratory diseases
  • Subjects with growth & development disorders
  • Subjects with malnutrition (<5% percentile) and obesity (>95% percentile).

Drop out criteria:

  • Subjects with cardiorespiratory disorder during intubation
  • Subjects who were failed to be intubated twice.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
SubjectsUSGUSG was used to measure the internal transversal subglottic diameter on the crichoid cartilago level while the head was in sniffing position. After USG measurement was recorded, Cole formula was used to measure internal diameter of uncuffed endotracheal tube.
SubjectsCole FormulaUSG was used to measure the internal transversal subglottic diameter on the crichoid cartilago level while the head was in sniffing position. After USG measurement was recorded, Cole formula was used to measure internal diameter of uncuffed endotracheal tube.
Primary Outcome Measures
NameTimeMethod
The accuracy proportion of USG and Cole Formula3 months

Whether the USG measurement and Cole Formula measurement accurate or not will be recorded.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Cipto Mangunkusumo Cental National Hospital

🇮🇩

Jakarta, DKI Jakarta, Indonesia