跳至主要内容
临床试验/NCT06428877
NCT06428877已完成不适用

Monocentric Retrospective Observational Study; Analysis of Gore Excluder ACS Device Using Numerical Simulation

Hospices Civils de Lyon1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2023年6月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
1
主要终点
The aim of the present study is to investigate the accuracy of numerical simulation to predict stent-graft apposition of Gore ACS in highly angulated proximal AAA necks.

研究概览

简要总结

andated when the risk of rupture is low and interventional treatment is offered to patients at high risk of rupture. Rupture risk is driven by aneurysm diameter and growth rate. Aneurysms with diameter greater than 55 mm and/or growth rate greater than 1 cm per year are at high risk of rupture. Open surgery and endovascular treatment are the two types of interventions. Open repair consists in replacing the aneurysmal part of the aorta using a synthetic fabric prosthesis after the abdomen has been opened and the aorta clamped. This invasive procedure is associated with a 3-10% post-operative mortality. Endovascular repair (EVAR) consists in excluding the aneurysm sac by inserting a self-expanding prosthesis (called stent-graft) through very small groin incisions, without abdominal opening nor aortic clamping. This minimally invasive procedure is associated with a significantly reduced post-operative mortality (around 1%) . However, hostile proximal neck anatomy including high angulation is associated with higher rates of type IA endoleak, reintervention and long-term mortality . For this reason, a conformable design of the Excluder stent-graft has been engineered with initial satisfactory results in patients with highly angulated or short necks . However, these satisfactory results have been obtained in carefully selected patients from experienced centers and a tool demonstrating adequate apposition of the Gore ACS is lacking. Study Device Description Numerical simulation has been used successfully to predict stent-graft behavior during FEVAR . Preliminary studies have also demonstrated to applicability of the technology to standard infrarenal devices , including in the setting of very tortuous anatomies9 . The potential of numerical simulation to predict stent-graft apposition of Gore ACS in highly angulated necks appears very promising to enhance patient selection.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

性别
All
接受健康志愿者

入选标准

  • The patient:
  • Is age ≥18 at the time of inclusion.
  • Underwent EVAR with ACS Gore Excluder
  • AAA proximal neck angulation superior to 60 degrees
  • Pre-op CT and post-operative/follow-up CT available

排除标准

  • Slice thickness of Pre-op or post-op / follow-up CT superior to 2mm.
  • Non-injected or poorly injected pre-operative CT-scan precluding technical feasibility of the aortic digital twin
  • Absence of post-operative or follow-up CT-scan
  • Patient refusal of his personal information/medical data to be used in the context of the study

结局指标

主要结局

The aim of the present study is to investigate the accuracy of numerical simulation to predict stent-graft apposition of Gore ACS in highly angulated proximal AAA necks.

时间窗: up to 16 months

Quantitative neck apposition parameters (including but not limited to malapposition length, width, angle) will be extracted both from numerical simulation and post-operative CT. Quantitative values will then be compared Comparison between quantitative neck apposition parameters (malapposition length, width, angle) derived from simulation and the one observed on post-op CT and/ or follow-up CT

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验