跳至主要内容
临床试验/NCT05752487
NCT05752487已完成不适用

Safety and Effectiveness Evaluation of the THERMOCOOL SMARTTOUCH SF Catheter With the TRUPULSE Generator for Treatment of Paroxysmal Atrial Fibrillation (PAF)

Biosense Webster, Inc.18 个研究点 分布在 4 个国家目标入组 149 人开始时间: 2023年2月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
149
试验地点
18
主要终点
Percentage of Participants With Primary Adverse Events (PAEs)

研究概览

简要总结

The purpose of this study is to demonstrate safety and effectiveness of the ablation system (THERMOCOOL SMARTTOUCH SF [STSF] catheter and TRUPULSE generator) when used for isolation of the atrial pulmonary veins (PVs) in treatment of participants with paroxysmal atrial fibrillation (PAF).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnosed with symptomatic paroxysmal atrial fibrillation (PAF) defined as atrial fibrillation (AF) that terminates spontaneously or with intervention within 7 days of onset. This PAF is considered to be symptomatic if symptoms related to AF are experienced by the participant
  • Selected for AF ablation procedure by pulmonary vein isolation (PVI)
  • Failed at least one antiarrhythmic drug (AAD) (class I to IV) as evidenced by recurrent symptomatic AF, or intolerable or contraindicated to the AAD
  • Willing and capable of providing consent
  • Able and willing to comply with all pre-, post- and follow-up testing and requirements.

排除标准

  • Previously known AF secondary to electrolyte imbalance, thyroid disease, or reversible or non-cardiac cause (example, documented obstructive sleep apnea, acute alcohol toxicity, morbid obesity {Body Mass Index greater than [>] 40 kilograms per meter square [kg/m²]}, renal insufficiency (with an estimated creatinine clearance less than [<] 30 milliliters [mL]/ minute [min]/1.73 meter square [m2] )
  • Previous left atrium (LA) ablation or surgery
  • Patients known to require ablation outside the pulmonary vein (PV) region (example, atrioventricular reentrant tachycardia, atrioventricular nodal reentry tachycardia, atrial tachycardia, ventricular tachycardia and wolff-parkinson-white)
  • Previously diagnosed with persistent AF [greater than (>) 7 days in duration]
  • Severe dilatation of the left atrium (LA) (Left anterior descending artery [LAD] >50mm antero-posterior diameter in case of Transthoracic Echocardiography [TTE])

结局指标

主要结局

Percentage of Participants With Primary Adverse Events (PAEs)

时间窗: 90 days post-procedure on Day 1

Percentage of participants with PAEs (within 7 days following the ablation procedure) was reported. PAEs included the following adverse events atrio-esophageal fistula, pulmonary vein stenosis, device or procedure related death, (that occurred greater than 7 days and less than or equal to 90 days post-procedure), phrenic nerve paralysis (permanent), cardiac tamponade/perforation, stroke/cerebrovascular accident (CVA), major vascular access complication/bleeding, thromboembolism, myocardial infarction, transient ischemic attack (TIA), pericarditis, heart block, pulmonary edema (respiratory insufficiency), and vagal nerve injury/gastroparesis.

Percentage of Participants With Acute Procedural Success

时间窗: Immediately post-procedure on Day 1

Percentage of participants with acute procedural success were reported. Procedural success was defined as electrical isolation of clinically relevant targeted pulmonary veins (PVs) (confirmed by entrance block) after adenosine/isoproterenol challenge at the end of the index ablation procedure.

次要结局

  • Percentage of Participants With Freedom From Documented (Symptomatic and Asymptomatic) Atrial Arrhythmia(Day 91 to Day 365)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (18)

Loading locations...