跳至主要内容
临床试验/NCT03201341
NCT03201341Unknown不适用

Cerebral Bases of Multisensory Perception of the Body and Its Action Space

Hospices Civils de Lyon1 个研究点 分布在 1 个国家目标入组 1,540 人开始时间: 2011年7月11日最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
1,540
试验地点
1
主要终点
Behavioural measure : accuracy

研究概览

简要总结

To accurately control body movements to interact with objects, our brain needs representations of the body and the nearby space. The broader aim of this research project is to study the behavioural and physiological mechanisms involved in the constitution of these representations, to identify their neural bases, in order to better understand the dysfunctions in the context of neurological or developmental disorders.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
5 Years 至 71 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Male or female aged 5 to 71
  • •Subject affiliated to the general social security scheme or a similar scheme
  • •Subject agreeing to participate in the study with informed consent -Capable of understanding information and simple instructions related to the study

排除标准

  • •Subject under tutelage or guardianship- Subject under tutelage or guardianship
  • •Subject not able to give informed consent, unable to receive information about the study
  • •Subject not affiliated to a French or non-French social security system holder of a European health insurance card

研究组 & 干预措施

Behavioral protocol

Other

To better understand the normal functioning of the brain within the framework of the representation of the body and of the space of action. During the experiment, physiological measurements will be recorded: electrical activity at the surface of the muscles (electromyography - EMG), scalp (electroencephalography - EEG) or skin (electrodermal response). Similarly, the movements of the arm will be recorded using an infrared kinematic system requiring simply the placement of markers at strategic points such as the tip of the thumb and forefinger, the wrist, the elbow ... Movements of the eyes can also be recorded, either with the aid of an electrooculograph (EOG) or with the aid of an infrared tracking device. Electrotactile stimulations of very low intensity and painless can also be administered.

干预措施: Electrooculogram (EOG) (Other)

Behavioral protocol

Other

To better understand the normal functioning of the brain within the framework of the representation of the body and of the space of action. During the experiment, physiological measurements will be recorded: electrical activity at the surface of the muscles (electromyography - EMG), scalp (electroencephalography - EEG) or skin (electrodermal response). Similarly, the movements of the arm will be recorded using an infrared kinematic system requiring simply the placement of markers at strategic points such as the tip of the thumb and forefinger, the wrist, the elbow ... Movements of the eyes can also be recorded, either with the aid of an electrooculograph (EOG) or with the aid of an infrared tracking device. Electrotactile stimulations of very low intensity and painless can also be administered.

干预措施: Surface Electromyography (EMG) (Other)

Behavioral protocol

Other

To better understand the normal functioning of the brain within the framework of the representation of the body and of the space of action. During the experiment, physiological measurements will be recorded: electrical activity at the surface of the muscles (electromyography - EMG), scalp (electroencephalography - EEG) or skin (electrodermal response). Similarly, the movements of the arm will be recorded using an infrared kinematic system requiring simply the placement of markers at strategic points such as the tip of the thumb and forefinger, the wrist, the elbow ... Movements of the eyes can also be recorded, either with the aid of an electrooculograph (EOG) or with the aid of an infrared tracking device. Electrotactile stimulations of very low intensity and painless can also be administered.

干预措施: Electrodermal response (Other)

Behavioral protocol

Other

To better understand the normal functioning of the brain within the framework of the representation of the body and of the space of action. During the experiment, physiological measurements will be recorded: electrical activity at the surface of the muscles (electromyography - EMG), scalp (electroencephalography - EEG) or skin (electrodermal response). Similarly, the movements of the arm will be recorded using an infrared kinematic system requiring simply the placement of markers at strategic points such as the tip of the thumb and forefinger, the wrist, the elbow ... Movements of the eyes can also be recorded, either with the aid of an electrooculograph (EOG) or with the aid of an infrared tracking device. Electrotactile stimulations of very low intensity and painless can also be administered.

干预措施: Changes in skin temperature (Other)

Study in fMRI

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to identify the brain areas critical for these functions and to determine their functional roles. The examination will consist of several very short scans at the very beginning and then a scan of about ten minutes intended to take a detailed anatomical image of the brain. Then, the subject will carry out the experimental task during one or more scan (s) whose cumulative duration will not exceed 45 minutes. The task accomplished is explained in detail by the experimenter.

干预措施: MRI (Other)

Study in MEG

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to identify the critical brain areas for these functions and to determine their functional roles and to study how They interact.The complete examination includes a magnetoencephalography (MEG) experiment followed by an MRI examination. The task accomplished is explained in detail by the experimenter.

干预措施: MRI (Other)

Study in MEG

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to identify the critical brain areas for these functions and to determine their functional roles and to study how They interact.The complete examination includes a magnetoencephalography (MEG) experiment followed by an MRI examination. The task accomplished is explained in detail by the experimenter.

干预措施: MEG (Other)

Study in TMS

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to determine the functional role of the brain areas involved in these processes. Before the Transcranial magnetic stimulation (TMS) examination, MRI of the brain will be performed.The TMS review will consist of three distinct sessions separated from one another by at least one week, depending on the protocol, and which will differ simply at the site or type of stimulation.

干预措施: MRI (Other)

Study in TMS

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to determine the functional role of the brain areas involved in these processes. Before the Transcranial magnetic stimulation (TMS) examination, MRI of the brain will be performed.The TMS review will consist of three distinct sessions separated from one another by at least one week, depending on the protocol, and which will differ simply at the site or type of stimulation.

干预措施: Transcranial magnetic stimulation (TMS) (Other)

Study in tDCS

Other

To better understand the normal functioning of the brain in the representation of the body and the space of action, to determine the functional role of the cerebral areas involved in these processes. The transcranial Direct Current Stimulation (tDCS) exam will consist of three separate sessions separated from each other by at least one week and will simply differ at the stimulation site. The task accomplished is explained in detail by the experimenter.

干预措施: Transcranial electrical stimulation in direct current (tDCS) (Other)

结局指标

主要结局

Behavioural measure : accuracy

时间窗: Day 30

Mesure of accuracy. Measurement of the accuracy of the realization of the implicit and explicit tasks according to the different approaches.

Number of particpants with changed kinematics , via 3D optoelectronic motion tracking systems

时间窗: Day 30

Both latency and amplitude measures will be analysed for the presence of altered mouvement patterns in velocity, accelleration, deceleration of the arm and grip formation for the hand.

Behavioural measure: reaction times

时间窗: Day 30

Mesure of reaction times.

次要结局

  • Neuronal response indices(Day 120)
  • Physiological Indices(Day 30)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验