Repeatability and Reproducibility of Lens Zonule Length Measurement Using ArcScan Insight 100
- Conditions
- Zonule of Zinn AbnormalityZonular Cataract
- Interventions
- Device: ArcScan Insight 100 very high-frequency digital ultrasound
- Registration Number
- NCT05657951
- Lead Sponsor
- Wenzhou Medical University
- Brief Summary
The purpose of this study is to evaluate the intra-examiner repeatability and inter-examiner reproducibility in lens zonule length measurements using very high-frequency (VHF) digital ultrasound (ArcScan Insight 100).
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- ACTIVE_NOT_RECRUITING
- Sex
- All
- Target Recruitment
- 45
- Subjects with no ocular disease except ametropia
- Subjects will be able to understand and willing to sign an informed consent
- Previous ocular surgery
- Subjects not being able to tolerate or not willing to use pilocarpine eye drops
- Subjects has active ocular infection or inflammation
- Subjects not being able to look steadily
- Subjects not being able to open eyes wide in sterile saline even after topical anesthesia
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Normal eyes ArcScan Insight 100 very high-frequency digital ultrasound -
- Primary Outcome Measures
Name Time Method Repeatability of ArcScan Insight 100 zonule scans in normal eyes (standard deviation and coefficient of variation) 1 day First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A.
Operator B then performed the measurements using the same procedure and technique.
The standard deviation and coefficient of variation of 3 repeated measurements for zonule length. will be calculated.Reproducibility of ArcScan Insight 100 zonule scans in normal eyes 1 day First, three images will be obtained under'capsule model'using ArcScan Insight 100, and the length of zonule will be measured with built-in software by operator A.
Operator B then performed the measurements using the same procedure and technique.
The intraclass correlation is used to evaluate the difference between operator A and operator B.
- Secondary Outcome Measures
Name Time Method Repeatability of zonule length measurement with the built-in software (the intraclass correlation) 1 month After a 1-month period, operator A and operator B will measure the zonule length again. The intraclass correlation is used to evaluate the difference between the two repeated measurements of one same image by Operator A or Operator B.
Trial Locations
- Locations (1)
Eye Hospital of WMU
🇨🇳Hangzhou, Zhejiang, China