Effects of Mobilization With Movement Floss Band (MWF) Application on Ankle Range of Motion, Weight-bearing Lunge Test, and Balance.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 50
- 试验地点
- 1
- 主要终点
- Weight bearing lunge test(WBLT)
研究概览
简要总结
Limited ankle mobility can affect functional movement and balance, even in healthy individuals. Floss band application is a technique in which an elastic band is wrapped around a joint during active movement to potentially improve joint mobility and functional performance. Another approach combines floss band application with mobilization with movement (MWF), which integrates joint mobilization techniques during movement.
This study examined the effects of floss band application on ankle range of motion (ROM), functional ROM, and static and dynamic balance in fifty healthy adults. Participants were randomly assigned to either a floss band group or a mobilization with movement floss band (MWF) group. Measurements were taken before and after the intervention.
详细描述
This study aimed to investigate the effects of floss band application on ankle joint range of motion (ROM), functional ROM, and static and dynamic balance ability in fifty healthy subjects. A pre-post experimental design was used.
Participants were randomly assigned to one of two groups: a floss band group or a mobilization with movement floss band (MWF) group. The floss band group received elastic band compression applied around the ankle joint during movement. The MWF group received floss band application combined with mobilization with movement techniques targeting the ankle joint.
Outcome measures included dorsiflexion (DF), weight-bearing lunge test (WBLT) performance, and assessments of static and dynamic balance. All measurements were conducted before and immediately after the intervention.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Investigator)
入排标准
- 年龄范围
- 20 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •No limited ankle joint ROM
- •No pain, edema, or sprain of weight bearing joint
- •No muscle fatigue due to radical work
- •No operation of lower extremity in one year
排除标准
- •lower extremity orthopedic problems
- •unstable steps and balance
- •visual impairments
研究组 & 干预措施
mobilization with movement floss band(MWF) group
In this study, to apply the pressure to the ankle joint, the floss band(Sanctband COMPRE Floss, LIME GREEN; PENTEL SDN.BHD., Shah Alam, Malaysia) was applied. The thickness of the floss band is 1.1 ㎜, the width is 5 ㎝ and the length is 2 m. In this study, to apply the pressure to the ankle joint, the floss band(Sanctband COMPRE Floss, LIME GREEN; PENTEL SDN.BHD., Shah Alam, Malaysia) was applied. The thickness of the floss band is 1.1 ㎜, the width is 5 ㎝ and the length is 2 m.
干预措施: Mobilization with movement floss band (MWF) intervention (Behavioral)
Floss band group
Apply the floss band(Sanctband COMPRE Floss, LIME GREEN; PENTEL SDN.BHD, Shah Alam, Malaysia) with mobilization while maintaining the DF position. Using a vertically folded floss band from the heel, band passes through the medial malleous and to the lateral malleous while gliding the talus with glade 3 level.
干预措施: Floss band intervention (Behavioral)
结局指标
主要结局
Weight bearing lunge test(WBLT)
时间窗: 1 year
The WBLT was measured to determine the DF of the ankle on functional condition. Participants placed the foot to be measured on the measuring tape perpendicular to the wall, measured the length from the big toe to the wall on the measuring tape. Lunge posture was performed so that the knee could touch the wall within a range where the heel of the measurement foot did not float, and if successful, the big toe of the measurement foot was more 1 ㎝ away from the wall and measured until failure. The last successful point was used as a measurement.
Range of motion(ROM)
时间窗: 1 year
A goniometer was used to measure the manual joint motion range of the ankle, and the operating range of DF and PF was measured. The axis was measured with the lateral malleolus, the stationary arm at the fibular head, and the moving arm parallel to the fifth metatarsal bone in the neutral state of the ankle
one leg test(OLT) - static balance ability
时间窗: 1 year
To measure the static balance ability of the ankle, OLT was measured using a wireless APDM Movement Monitoring inertial sensor system(APDM Inc, Portland, OR, USA). OLT was performed for 30 seconds to measure the sway area, and decrease sway area mean improving static balance. Three synchronized Opal inertial sensors were equipped on both ankles and lumbar L5 via straps. The signal is sampled, automatically processed, calculated, and streamed to a laptop via the corresponding "Mobility LabTM" software package(Mobility LabTM, Arlington, VA, USA). The OLT was conducted for 30 seconds, and when the starting sound was heard, the target person was instructed to stand with one foot and balance. If the foot touched the ground 30 seconds before, it was considered a failure and carried out again.
Y-balance test - Dynamic balance ability
时间窗: 1 year
The Y-balance test Lower Quarter(YBT-LQ; Move2Perform, Evansville, IN, USA) was used to measure the dynamic balance of the ankle. YBT-LQ consists of three pipes and one plate, and there is an indicator for measurement on each pipe. YBT-LQ has pipes in three directions from the support to the anterior(ANT), posterior lateral(PL) direction, and posterior medial(PM) direction, and the angle between the front and back pipes is 135°, and the pipe angle between the back inner and back sides is 90°. Every pipe is marked with distances in 0.5 cm. The subject's measurement foot is started in a single leg stance state by attaching the big toe to the red line of the plate. With the unsupported foot, the indicator in each direction should be reached to the tip of the toe to the maximum and returned again.
次要结局
未报告次要终点
研究者
Boung-hyoun Moon
Clinical Professor
Nambu University
