跳至主要内容
临床试验/NCT00323024
NCT00323024撤回2 期

An Open-Label, Dose-Determination Safety, Tolerability, and Activity Study of Inhaled NX1011 in Patients With Pulmonary Arterial Hypertension

NITROX, LLC12 个研究点 分布在 1 个国家目标入组 72 人开始时间: 2006年9月最近更新:
适应症
相关药物

试验速览

阶段
2 期
状态
撤回
发起方
NITROX, LLC
入组人数
72
试验地点
12
主要终点
To evaluate the safety, tolerability, and activity of inhalation therapy with NX1011 based on right heart catheterization (RHC) measures, pulse oximetry, and hemodynamic response

研究概览

简要总结

The purpose of this study is to determine the safety and maximum tolerated dose of inhaled NX1011 for the treatment of pulmonary arterial hypertension (PAH).

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient must either:
  • meet the PAH diagnostic criteria at Screening (based on a documented history of diagnosis as outlined in the American College of Chest Physicians [ACCP] 2004 Evidence-Based Clinical Practices Guidelines)15; or
  • have elevated pulmonary pressure with a suspected PAH diagnosis based on a clinical referral at Screening for a RHC.
  • Patient must have PAH as defined by a mean pulmonary artery pressure (PAP) > 25 mmHg.
  • Patient must have symptoms of pulmonary hypertension (PH) according to the World Health Organization (WHO) Functional Classification of Pulmonary Hypertension Class II through IV.
  • Patient must consent to, be able to tolerate, and have adequate venous and arterial access for Swan-Ganz catheterization (SGC) and an arterial line.

排除标准

  • Clinically significant right-to-left intracardiac shunts based on Doppler echocardiography with bubble study.
  • History of pulmonary veno-occlusive disease or clinically significant aortic or mitral stenosis.
  • History of sustained ventricular tachycardia (VT-S) or ventricular fibrillation (VF) and cardiac arrest, or presence of atrial fibrillation.
  • Active cardiac disease meeting the following criteria:
  • Patient with elevated pulmonary capillary wedge pressures (PCWPs) > 25 mmHg.
  • Patient with a history of myocardial infarction or coronary intervention within the last 60 days.
  • Patient with a history of pacemaker, cardiac defibrillator, or biventricular pacemaker insertion within 4 weeks of Baseline.
  • Patient who cannot be withdrawn from nitrate therapy.

结局指标

主要结局

To evaluate the safety, tolerability, and activity of inhalation therapy with NX1011 based on right heart catheterization (RHC) measures, pulse oximetry, and hemodynamic response

To establish maximum tolerated dose (MTD) levels of NX1011 based on predefined criteria for dose-limiting toxicity (DLT)

To qualify the delivery apparatus

To generate descriptive data on the concentration-response relationship in order to choose a range of concentrations (e.g., low, medium, high) for the follow-up, fixed-dose, placebo-controlled study

To summarize correlation data between echocardiography and RHC measures with respect to activity and methemoglobin levels documented via the visible light spectroscopy

次要结局

  • To summarize correlation data between echocardiography and RHC measures with respect to activity and methemoglobin levels documented via the visible light spectroscopy

研究者

发起方
NITROX, LLC
申办方类型
Industry

研究点 (12)

Loading locations...

相似试验