Comparison of Fitting Methods Using Cochlear Clinical Care Innovation

Cochlear3 sites in 2 countries48 target enrollmentNovember 2014
ConditionsHearing Loss

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Hearing Loss
Sponsor
Cochlear
Enrollment
48
Locations
3
Primary Endpoint
Speech perception performance in subjects fitted with Nucleus Fitting Software and subjects fitted with Nucleus Custom SoundTM Suite assessed via aided hearing thresholds
Status
Completed
Last Updated
8 years ago

Overview

Brief Summary

The purpose of this study is to evaluate if the new and simplified fitting method with Cochlear Nucleus Fitting Software (a major component of a suite of tools which form the Clinical Care Innovation) provides Cochlear Implants Recipients with the same hearing outcome as the current and established clinical fitting method with Cochlear Nucleus Custom SoundTM Suite. The Clinical Care Innovation method reduces fitting to simple volume, bass and trebles adjustments, operations which are familiar to anyone who has used an audio player.

Registry
clinicaltrials.gov
Start Date
November 2014
End Date
December 15, 2017
Last Updated
8 years ago
Study Type
Interventional
Study Design
Crossover
Sex
All

Investigators

Sponsor
Cochlear
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Newly implanted subjects with available Nucleus Cochlear Implants compatible with CP900 series sound processors (excluding Cochlear Nucleus Hybrid)
  • Post linguistically deafened adults (≥ 18 years)
  • Unilaterally implanted
  • ≤ 15 years of severe to profound deafness prior to implantation
  • Subjects who are capable and willing to participate in speech perception tests in local language
  • Subjects who are able to provide feedback in form of a written questionnaire (e.g. Speech Spatial Hearing Qualities questionnaire)
  • Subjects willing to give their consent to the study

Exclusion Criteria

  • Additional handicaps that would prevent participation in evaluations (e.g. visual impairment, blindness)
  • Unrealistic expectations on the part of the subject, regarding the possible benefits, risks and limitations that are inherent to the procedure/fitting method
  • Bilateral implantation
  • Hybrid-L (not supported by Nucleus Fitting Software)
  • Subjects who already have hearing experience with a Cochlear Implant (e.g. reimplantation, contralateral Cochlear Implant)
  • Subjects with single-sided deafness
  • Known cochlea malformations
  • Subjects who lost their hearing due to meningitis

Outcomes

Primary Outcomes

Speech perception performance in subjects fitted with Nucleus Fitting Software and subjects fitted with Nucleus Custom SoundTM Suite assessed via aided hearing thresholds

Time Frame: 15 months after implantation

Adaptive Oldenburg Sentence Test in noise with speech at 65 dB (if the subject's understanding with Oldenburg Sentence Test in quiet is ≥ 70%).

Speech perception performance in subjects fitted with Nucleus Fitting Software and subjects fitted with Nucleus Custom SoundTM Suite assessed via speech performance tests

Time Frame: 15 months after implantation

Freiburg Monosyllables and Oldenburg Sentence Test in quiet at 65 dB.

Secondary Outcomes

  • Hearing disability score in subjects fitted with Nucleus Fitting Software and subjects fitted with Nucleus Custom SoundTM Suite assessed via the Speech Spatial Hearing Qualities questionnaire (without spatial part)(15 months after implantation)
  • Subject preference for fittings performed with Nucleus Fitting Software and fittings with Nucleus Custom SoundTM Suite assessed via a subject comfort questionnaire(after each fitting (12 months after implantation))

Study Sites (3)

Loading locations...

Similar Trials