Skip to main content
Clinical Trials/NCT04540302
NCT04540302CompletedNot Applicable

Prospective, Randomized, Controlled, Multicenter Study Comparing the Merit WRAPSODY™ Endovascular Stent Graft to Percutaneous Transluminal Angioplasty for Treatment of Venous Outflow Circuit Stenosis or Occlusion in Hemodialysis Patients. The WAVE Study

Merit Medical Systems, Inc.80 sites in 4 countries357 target enrollmentStarted: March 9, 2021Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
357
Locations
80
Primary Endpoint
Proportion of subjects without any localized or systemic safety events (Primary Safety Endpoint)

Study Overview

Brief Summary

The purpose of the study is to demonstrate the safety and efficacy of the Merit WRAPSODY Endovascular Stent Graft for treatment of stenosis or occlusion within the dialysis access outflow circuit

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Subject provides written informed consent
  • Subject is male or female, with an age ≥ 18 years at date of enrollment.
  • Subject is willing to undergo all follow-up assessments.
  • Subject has a life expectancy ≥ 12 months.
  • Subject is undergoing chronic hemodialysis.
  • Subject has either a mature AVF or AVG in the arm.
  • Target lesion(s) involves a de novo stenotic or non-stented restenotic lesion.
  • Target lesion has ≥50% stenosis.
  • Target lesion(s) reference vessel diameter is between 5.0 mm and 14.0 mm

Exclusion Criteria

  • Subject has a known or suspected infection of the hemodialysis access site, systemic infection and/or septicemia.
  • Subject has a stroke diagnosis within 3 months prior to enrollment.
  • Subject has a history of unstable angina or myocardial infarction within 60 days prior to enrollment.
  • Subject is pregnant, breastfeeding, or intending to become pregnant within the next year.
  • Target lesion is located within a stent / stent graft.

Arms & Interventions

AVF Peripheral study treatment group

Experimental

Subjects randomised to treatment with the WRAPSODY Endovascular Stent Graft

Intervention: Merit WRAPSODY Endovascular Stent Graft (Device)

AVF Peripheral control group

Other

Subjects randomised to treatment with standard percutaneous transluminal angioplasty (PTA)

Intervention: PTA (Device)

AVG Anastomosis

Experimental

All subjects in this single arm cohort will receive treatment with the WRAPSODY Endovascular Stent Graft

Intervention: Merit WRAPSODY Endovascular Stent Graft (Device)

Outcomes

Primary Outcomes

Proportion of subjects without any localized or systemic safety events (Primary Safety Endpoint)

Time Frame: 30 days

Proportion of subjects without any localized or systemic safety events through 30 days post-index procedure that affect the access or venous outflow circuit and resulted in reintervention, hospitalization, or death (not including stenosis or thrombosis). Endovascular procedures performed to treat safety events after the index study procedure will be considered surgeries.

Proportion of subjects with Target Lesion Primary Patency (TLPP) (Primary Effectiveness Endpoint:)

Time Frame: 6 months

Proportion of subjects with Target Lesion Primary Patency (TLPP) at 6 Months. TLPP is defined as freedom from clinically-driven target lesion revascularization (CD-TLR) or target lesion thrombosis measured through 6 months post-procedure, which is the time interval of uninterrupted patency after study procedure to the next intervention performed on the target lesion or uncorrectable target lesion occlusion.

Secondary Outcomes

  • Rates of procedure- and device-related adverse events involving the access circuit(Index procedure, 30 days, and months 6, 12 and 24.)
  • Proportion of subjects with Target Lesion Primary Patency(12 and 24 months)
  • Proportion of subjects with Assisted Target Lesion Primary Patency (aTLPP)(6, 12 and 24 months)
  • Proportion of subjects with Access Circuit Primary Patency (ACPP)(6, 12 and 24 months)
  • Proportion of subjects with Post-Procedure Secondary Patency(6, 12 and 24 months)

Investigators

Sponsor Class
Industry
Responsible Party
Sponsor

Study Sites (80)

Loading locations...