跳至主要内容
临床试验/NCT02966496
NCT02966496Unknown不适用

Safety and Efficacy of Implantation of Two Multifocal Intraocular Lenses in the Treatment of Senile Cataract: a Randomized Controlled Clinical Trial

Qinghai University0 个研究点目标入组 40 人开始时间: 2016年1月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
40
主要终点
Number of cataract participants with good biocompatibility of intraocular lens implants

研究概览

简要总结

This trial is designed to compare the biocompatibility and long-term visual outcomes of the Tecnis Z9001 and Acri.LISA 366D multifocal IOLs used for the treatment of senile cataract. The aim is to provide a safer biomaterial for senile cataract treatment, achieving better postoperative visual quality and fewer complications.

详细描述

History and current studies Aging-induced degenerative diseases are the leading cause of senile cataract. Phacoemulsification with intraocular lens (IOL) implantation is a commonly employed surgical technique for the treatment of cataract. A traditional IOL is spherical and monofocal. Traditional monofocal IOL implantation allows cataract patients to obtain good postoperative distance vision but loss of accommodation results in poor near vision. Following monofocal IOL implantation, most patients still require the use of glasses. Fortunately, the presence of multifocal IOLs solves this problem. Studies have shown that aspheric IOLs with zero or negative spherical aberration can eliminate or reduce the spherical aberration of the whole eye and can improve contrast sensitivity and night vision compared with a spherical IOL.

As first reported in 1987 by Keatea et al., multifocal IOLs were introduced to provide improved visual acuity, thus eliminating the need to wear glasses and improving the patient's quality of life. Increasing evidence-based medicine evidences have shown that multifocal IOLs are more adept to improving near vision than single-focus IOLs. To date, various types of multifocal IOLs have been developed and according to different design principles, clinically used multifocal IOLs have been divided into refraction type, diffraction type and refraction/diffraction type. Introduced in 2002, the Tecnis Z9001 diffractive multifocal aspherical IOL (Abbott Medical Optics, CA, USA) is clinically proven to give patients improved contrast vision and visual quality when compared with the common IOL, although deficiencies include postoperative glare and reduced contrast sensitivity. Emerging designs for multifocal IOLs aim to provide improvements in postoperative visual quality. The Acri.LISA 366D multifocal aspheric IOL is a relatively novel refractive/diffractive multifocal IOL that is different from traditional IOLs. Its unique optical design improves the patient's full vision and reduces the incidence of light scattering, glare and halo, which is expected to deliver better clinical outcomes. However, its long-term clinical performance and the potential incidence of complications still need further evaluation.

It is worth noting that as age increases, the increase in presbyopia, aberrations and lens scattering reduces the compensation for corneal aberrations, thereby resulting in a decrease in visual acuity and contrast sensitivity. Given this, ideal IOLs should have good biocompatibility and good resolution with no spherical aberration.

Data collection, management, analysis, and open access Data collection Clinical data will be collected and managed using an electronic data capture system. All data relevant to the trial will be recorded in electronic case report forms that will be provided by the sponsor personnel. The case report will be completed after the interview.

Data management After completion of follow-up and data confirmation, only the project manager will lock the database. The locked data will be unable to be altered and will be preserved for future reference by the Affiliated Hospital of Qinghai University in China.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
50 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Clinically diagnosed as age-related cataract.
  • Corneal astigmatism < 1.0 D
  • Lens hardness, II-III
  • Initial surgery on the eye
  • Age 50-80 years
  • Healthy and able to tolerate anesthesia and surgery

排除标准

  • Glaucoma or secondary vision loss resulting from diabetes, hypertension, intracranial tumors and neurological diseases
  • Fundus disease, corneal edema, corneal opacity, endophthalmitis, and/or iris adhesion.
  • Prior experience of eye surgery
  • Failure to make regular referrals
  • Autoimmune disease, mental illness or other serious systemic disease
  • Inability to cooperate with the researchers
  • Inability to tolerate surgery
  • Sensitivity, anxiety or the pursuit of perfection
  • Inability to give informed consent

结局指标

主要结局

Number of cataract participants with good biocompatibility of intraocular lens implants

时间窗: month 12 after surgery

Good engraftment, epithelialization, no neovascularization, retained transparency, no host inflammatory reaction.

次要结局

  • Visual acuity(at month 1, month 3, month 6, month 12 and month 24 after surgery)

研究者

发起方
Qinghai University
申办方类型
Other
责任方
Sponsor

相似试验