跳至主要内容
临床试验/NCT02209532
NCT02209532已完成不适用

A Randomized, Prospective, Open Label, Multicenter Study Assessing the Safety and Utility of PINPOINT® Near Infrared Fluorescence Imaging in the Identification of Lymph Nodes in Patients With Uterine and Cervical Malignancies Who Are Undergoing Lymph Node Mapping

Novadaq Technologies ULC, now a part of Stryker8 个研究点 分布在 3 个国家目标入组 180 人开始时间: 2015年12月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
180
试验地点
8
主要终点
Effectiveness of PINPOINT and IC2000 in the Identification of Lymph Nodes Defined as the Proportion of Confirmed Lymph Nodes Identified

研究概览

简要总结

This is a randomized, prospective, open label, multicenter study to assess the safety and utility of PINPOINT® Near Infrared Fluorescence Imaging (PINPOINT) in identification of lymph nodes (LN) in patients with uterine and cervical malignancies who are undergoing LN mapping.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • 18 years of age or older
  • Subjects with FIGO Clinical Stage I endometrial cancer undergoing minimally invasive hysterectomy with lymph node mapping.
  • Subjects with FIGO Clinical Stage IA cervical cancer ≤ 2 cm in size undergoing minimally invasive hysterectomy, trachelectomy, or conization with lymph node mapping. Subjects with clinical Stage IA1 cervical cancer without lympho vascular space involvement (LVSI) and negative margins on cone biopsy are not to be included.
  • Subjects with negative nodal status (N0)
  • Subjects with negative metastatic involvement (M0).

排除标准

  • Have had prior dissection and/or radiation in pelvis.
  • Advanced cervical or endometrial cancer, T3/T4 lesions
  • Diagnosis of cervical cancer with a tumor size greater than 2 cm.
  • Locally advanced or inflammatory cervical or uterine cancer
  • Metastatic cervical or uterine cancer.
  • Known allergy or history of adverse reaction to ICG, iodine or iodine dyes.
  • Known allergy or history of adverse reaction to Blue dye (Isosulfan blue) or triphenylmethane.
  • Hepatic dysfunction defined as MELD Score >
  • Renal dysfunction defined as serum creatinine ≥ 2.0 mg/dl.
  • Subjects who have participated in another investigational study within 30 days prior to surgery.
  • Pregnant or lactating subjects.
  • Subjects who, in the Investigator's opinion, have any medical condition that makes the subject a poor candidate for the investigational procedure, or interferes with the interpretation of study results.

研究组 & 干预措施

Blue - PINPOINT

Active Comparator

The cervix will be injected 4 times with a 1ml solution of 1% Isosulfan blue followed by injection 4 times of 1 ml of 1.25 mg/ml solution of ICG. LN mapping with Blue dye will be performed until the investigator identifies all blue nodes or determines that blue nodes cannot be identified. Once complete, the Investigator will begin mapping with PINPOINT until all 'ICG' nodes are identified or the investigator determines that 'ICG' nodes cannot be identified. Once mapping with both Blue dye and PINPOINT have been completed and documented, LNs identified with Blue dye or PINPOINT will be excised.

干预措施: PINPOINT (Device)

PINPOINT - Blue

Active Comparator

The cervix will be injected 4 times with 1 ml of a 1.25 mg/ml solution of ICG followed by injection 4 times of a 1 ml solution of 1% Isosulfan blue. LN mapping with PINPOINT will be performed until the investigator identifies all 'ICG' nodes or determines that 'ICG' nodes cannot be identified. Once complete, the Investigator will begin mapping with Blue dye until all 'blue' nodes are identified or the investigator determines that 'blue' nodes cannot be identified. Once mapping with both Blue dye and PINPOINT have been completed and documented, LNs identified with Blue dye or PINPOINT will be excised.

干预措施: PINPOINT (Device)

结局指标

主要结局

Effectiveness of PINPOINT and IC2000 in the Identification of Lymph Nodes Defined as the Proportion of Confirmed Lymph Nodes Identified

时间窗: Day 0

To assess the effectiveness of intraoperative PINPOINT Near Infrared Fluorescence Imaging in the identification of lymph nodes in subjects with uterine and cervical malignancies who are undergoing lymph node mapping.

次要结局

  • Effectiveness of PINPOINT and Blue Dye in the Identification of at Least One Lymph Node Defined as the Number of Subjects in Which at Least One Confirmed Lymph Node Was Identified With Either PINPOINT or Blue Dye(Day 0)
  • Effectiveness of PINPOINT and Blue Dye in the Identification of Bilateral Lymph Nodes Defined as the Number of Subjects in Which Lymph Nodes Were Identified Bilaterally With Either PINPOINT or Blue Dye.(Day 0)
  • Identification of Lymph Nodes Following Lymphatic Channels Defined as the Number of Subjects in Which Confirmed Lymph Nodes Were Identified by Following a Lymphatic Channel With Either PINPOINT or Blue Dye.(Day 0)
  • Safety of Interstitial Injection of ICG Defined as the Number of Adverse Effects Related to ICG(Day 0 to Day 30)
  • Anatomic Distribution of Lymph Nodes(Day 0)

研究者

发起方
Novadaq Technologies ULC, now a part of Stryker
申办方类型
Industry
责任方
Sponsor

研究点 (8)

Loading locations...

相似试验

A Study Assessing the Safety and Utility of... | 临床试验