跳至主要内容
临床试验/NCT06212466
NCT06212466已完成不适用

Magnetocardiography as a Noninvasive Diagnostic Strategy for Suspected Myocardial Ischemia With No Obstructive Coronary Artery Disease

Genetesis Inc.8 个研究点 分布在 1 个国家目标入组 136 人开始时间: 2024年6月3日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
136
试验地点
8
主要终点
Diagnostic accuracy of CardioFlux MCG in determining the presence of CMD

研究概览

简要总结

A prospective, multicenter, observational, single-arm trial to validate CardioFlux MCG's ability to diagnose myocardial ischemia caused by coronary microvascular dysfunction in patients with suspected ischemia and confirmed no obstructive coronary artery disease (suspected INOCA) by using diagnostic measures of coronary flow reserve (CFR) via invasive angiography as a reference standard for diagnosis.

详细描述

Magnetocardiography (MCG) is a noninvasive imaging modality that has been extensively studied over the past several decades as a diagnostic imaging solution for various forms of cardiovascular disease. MCG measures the magnetic field that arises from the electrical activity of the heart's pacemaker activity, the very same activity which yields surface electric field potentials as measured by the electrocardiogram. Unlike electrocardiographic signals, however, MCG signals are undistorted by conductive tissue noise, and are highly sensitive to ischemic injury and vortex currents missed by the same electrocardiographic measurements. Accordingly, numerous clinical trials suggest the usefulness of MCG for the evaluation of ischemia in patients with suspected acute coronary syndrome.

There is a growing body of evidence demonstrating the usefulness of MCG in the detection of myocardial ischemia, both in patients with symptoms of ACS, and in patients with stable angina. Since MCG is a functional assessor of depolarization and repolarization heterogeneity, it is hypothesized that MCG may be a useful frontline diagnostic modality to identify CMD in patients who would otherwise have normal coronary CT angiograms and/or stress tests. The proposed study intends to study the diagnostic accuracy of MCG in patients with suspected INOCA.

This demonstrates a significant unmet clinical need in the assessment of patients, and especially women, with INOCA. The current standard of care for these patients is resource/time intensive and associated with a significant rate of non-diagnostic clinical data requiring expensive and invasive evaluation for safe patient management. Magnetocardiography offers the potential for rapid, safe, noninvasive, non-radiologic assessment of the INOCA population, and may lead to earlier treatment strategies for CMD patients.

From the participating clinical sites, patients age ≥18 years who presented with chest pain or exertional dyspnea concerning for myocardial ischemia with no obstructive epicardial CAD on invasive or computed tomographic coronary angiography will be screened and subsequently enrolled when meeting criteria. This is a prospective observational study used for clinical data collection for the clinical validation testing of the CardioFlux MCG system. There will be no intervention introduced by the study device. The interpretation of the CardioFlux MCG data made by the study reader(s) will not be known to the patient's treating physician. Similarly, the patient's coronary physiology data, diagnosis, or interventions made by the patient's treating physician in following the standard of care will not be known to any of the scan readers. Except for the introduction of the MCG scan, there will be no other alteration to the patient standard of care.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Other

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Diagnostic accuracy of CardioFlux MCG in determining the presence of CMD

时间窗: 6 months

Diagnostic accuracy of CardioFlux MCG in determining the presence of coronary microvascular dysfunction, as measured by AUC with ground truth defined as an invasive CFR \<2.5 for bolus thermodilution method. H0: AUC\<0.55 Ha: AUC≥0.55

次要结局

  • Participant Age(6 months)
  • Sensitivity and specificity in determining presence of CMD (Rule In)(6 months)
  • Participant Height(6 months)
  • Number of Adverse Events(6 months)
  • Sensitivity and specificity in determining presence of CMD (Rule Out)(6 months)
  • ROC/AUC, sensitivity and specificity at CFR cut-offs of <2.0 and 3.0.(6 months)
  • Patient-Reported Experiences with CardioFlux(6 months)
  • Participant Weight(6 months)
  • Participant Gender at Birth(6 months)
  • Index of Microvascular Resistance (IMR)(6 months)
  • Comparison of bolus vs. continuous thermodilution(6 months)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (8)

Loading locations...

相似试验