Gap CO2 in Septic Patient to Predict Cardiomyopathy Septic
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 98
- 试验地点
- 1
- 主要终点
- gapCO2
研究概览
简要总结
the investigators included 98 patients admitted for sepsis and septic shock (68.4% men, 31.6% women) with an average age of 60.42 years ± 15.13, ranging from 21 to 96 years. The average length of hospital stay was 7.53 days. The most noted medical histories were diabetes (38.8%), hypertension (28.6%), and renal insufficiency (17.1%). Regarding laboratory findings: the mean white blood cell count was 15,985.16 cells/mm³, the mean C-reactive protein (CRP) level was 227.69 mg/L, and the mean procalcitonin level was 50.43 µg/L. In terms of blood gas analysis: the mean lactate level was 3.67 mmol/L, and the mean PCO2 gap (DELTAPCO2) was 4.85. All our patients were continuously monitored by pulse wave analysis: the mean cardiac output was 5.69 L/min, and the mean cardiac index was 4.14 L/s/m² All our patients underwent an echocardiogram, which is a routine examination in our department and is performed at the patient's bedside. The average left ventricular ejection fraction (LVEF) was 51.73%, and the average subaortic peak velocity (ITV) was 14.66 cm.
Subsequently. the investigators examined the clinical and paraclinical profile of patients with septic cardiomyopathy. the investigators identified 19 patients with this condition, while 79 patients did not exhibit cardiac involvement. The percentage was significantly higher in the population with cardiac involvement, accounting for 28.3%. Among the patients with cardiac involvement, 76.5% had a PCO2 gap (DELTAPCO2) ≥ 6 mmHg, a significantly reduced cardiac output with an average of 3.3 L/min, and a predominantly low cardiac index, with 64.3% having an index < 2.2 L/min/m². The mortality rate was significantly increased at 73.7%.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Patients admitted to the intensive care unit
- •sepsis or septic shock
- •at least one echocardiogram and were monitored by pulse wave contour analysis
- •stay of 72 hours in the intensive care unit
排除标准
- •Patients without sepsis or septic shock.
- •Patients with COVID-
- •Patients who died within 48 hours of hospitalization.
- •Cases with incomplete medical records or patients not monitored.
- •Patient with pre-existing cardiac conditions.
- •post-operative patients from cardiac and thoracic surgeries.
结局指标
主要结局
gapCO2
时间窗: 10 mounths
significative in cardiomyopathy septic
次要结局
未报告次要终点
研究者
Younes Oujidi
doctor
Mohammed VI University Hospital