跳至主要内容
临床试验/NCT03252574
NCT03252574已完成不适用

To Explore the Physiological Impact of AIR+ Smart Masks on Children

Innosparks Pte Ltd.2 个研究点 分布在 1 个国家目标入组 106 人开始时间: 2016年7月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
106
试验地点
2
主要终点
End Tidal Carbon Dioxide

研究概览

简要总结

The primary objective is to evaluate the physiological impact of AIR+ Smart Masks on end-tidal carbon dioxide (ETCO2) of children aged 7 to 14 years of age. The secondary outcomes include other physiological parameters such as oxygen saturation (SPO2), heart rate (HR) and respiratory rate (RR). In addition, we will assess the general well-being and comfort level of the child when wearing the AIR+Smart Mask with and without micro-ventilator.

详细描述

Studies have shown that prolonged wearing of disposable particulate respirators may lead to an increase in carbon dioxide (CO2) levels in the dead space of the respirator as well as in the re-breathing of the expired air when wearing it. The increased CO2 levels may result in headaches, increased irritability, and breathing difficulty. In addition, there is some discomfort due to the accumulation of heat and humid air in the dead space of between the respirator and face. Innosparks Pte Ltd (formerly, ST Dynamics) (the Advanced Engineering Centre of ST Engineering) developed a new type of disposable particulate respirator (hereon referred to as AIR+ Smart Mask) that is suitable for use in both adults and children, from ages 7 and above.They also designed an optional accompanying device, the micro-ventilator, which is battery-powered and aims to extract accumulated heat, moisture, and carbon dioxide from within the mask. Innosparks Pte Ltd (formerly, ST Dynamics) have obtained the US National Institute for Occupational Safety and Health (NIOSH) N95 certification for the three sizes of masks without micro-ventilator, and Conformité Européenne's (CE) certification for the following mask specifications:• FFP1 and NIOSH approved N95 for S and M-sized AIR+ Smart Masks without micro ventilator;• FFP2 and NIOSH approved N95 for L-sized mask without micro ventilator;• FFP1 certification for S and M-sized masks with micro-ventilator, and;• FFP2 certification for the L size mask with micro-ventilator.For purposes of this research, both CE and NIOSH markings will be made for the masks trialed.As the masks were developed specifically for school-going children, this study is designed to explore whether the new disposable particulate respirator, which can be attached with a ventilator to vent out expired air within the respirator, is safe and effective for use in healthy children aged 7 to 14 years of age. This is through measuring the variation of carbon dioxide levels in children with and without the AIR+ Smart Mask. End-tidal carbon dioxide pressure (ETCO2) is a good indicator of arterial carbon dioxide pressure (PaCO2) in healthy adults and children, and has been used for continuous direct assessment of PaCO2 in clinical contexts. The normal range of PaCO2 is from 35 - 45 mmHg. As there is a slight margin of difference between ETCO2 and PaCO2 values during measurement of about 1.6 +/- 4.3mmHg, this study defines 30 to 50mmHg as the acceptable range for ETCO2 levels.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
None

入排标准

年龄范围
7 Years 至 14 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Aged between 7 and 14 years of age (inclusive)
  • Subjects and their parent/legal guardian must provide the consent and assent as appropriate to take part in this study.

排除标准

  • Subjects with any known cardiorespiratory conditions (including but not limited to the following: asthma, bronchitis, cystic fibrosis, congenital heart disease, emphysema)
  • Subjects with any known medical conditions that may be exacerbated by strenuous activity, including but not limited to the following: exercise-induced asthma, lower respiratory infection (including pneumonia, bronchitis) in the past 2 weeks, anxiety disorders, diabetes, hypertension, or epilepsy/ seizure disorder
  • Subjects with any physical disability from medical, orthopaedic or neuromuscular disorders
  • Subjects who have an acute upper respiratory tract infection/ moderately severe rhinitis (i.e. blocked nasal passages) on the day of the study
  • Subjects who may compromise the integrity of the mask fit (e.g. those with excessive facial hair).

结局指标

主要结局

End Tidal Carbon Dioxide

时间窗: 75 minutes

次要结局

  • Heart Rate(75 minutes)
  • Percent Oxygen Saturation(75 minutes)
  • Respiratory Rate(75 minutes)

研究者

发起方
Innosparks Pte Ltd.
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验