A Comparison of Two GlideScope Intubation Techniques - Effect on Hemodynamic Changes and Injury Rate

Samuel Lunenfeld Research Institute, Mount Sinai Hospital2 个研究点 分布在 1 个国家目标入组 81 人开始时间: 2013年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
81
试验地点
2
主要终点
Hemodynamic response to tracheal intubation

研究概览

简要总结

The aim of this study is to compare the hemodynamic response to tracheal intubations using the standard technique versus the alternative GS intubation technique. As secondary outcomes the investigators will analyze procedure time, success rate and injury rate.

The investigators hypothesize that the alternative intubation technique will have a shorter procedure time and lower injury rate when compared to the standard technique of GS intubation.

详细描述

A Difficult intubation is still one of the most daunting challenges in anesthesiology. One of the tools used to assist with a difficult tracheal intubation is the GlideScope (GS) (Verathon, Bothell, WA, USA). The GS is a video laryngoscope that has a 60 degree angle blade with a built-in high-resolution camera and a light source assembled beside it. The image is transmitted onto a mobile bedside monitor. It has been widely used in medicine for over a decade. The GS was designed to provide an improved view of the glottis during difficult intubations without alignment of the oral, pharyngeal and tracheal axes, as it is able to "look around the corner" to facilitate the intubation.

The standard technique of the GS intubation involves a midline laryngoscopy followed by the insertion of a styleted endotracheal tube (ETT) once an adequate view of the vocal cords has been achieved. The ETT insertion process requires the operator to look away from the monitor during the laryngoscopy while maintaining the blade position in order to insert it into its initial position.

An alternative GS intubation technique has been described for cases in which there is limited mouth opening, a big tongue or other anatomical impediments. In these cases the ETT is inserted under direct vision as a "fish hook" at the side of the mouth before the GS blade is introduced into the oropharynx.

There are several advantages to this alternative technique. The first advantage is that this technique of ETT insertion would minimize the laryngoscopy time as a part of it is performed before the blade is introduced and the stimulating effect occurs. This technique thus has the potential of reducing the sympathetic response. Minimizing oropharyngo-laryngeal stimulation time would theoretically attenuate the hemodynamic response.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients of ASA physical status 1-2
  • Patients aged 18 years and older
  • Patients undergoing elective surgery that requires tracheal intubation

排除标准

  • Patients in whom a rapid sequence intubation or alternative intubation method is indicated
  • Patients with a known or suspected oral, pharyngeal or laryngeal mass
  • Patients previously flagged as a difficult intubation
  • Patients with hypertension (treated or untreated, poor dentition, symptomatic gastro-esophageal reflux or cervical spine instability

结局指标

主要结局

Hemodynamic response to tracheal intubation

时间窗: 24 hours

Heart rate and non-invasive blood pressure will be measured before induction, and throughout and after laryngoscopy and induction

次要结局

  • Procedure time(10 minutes)
  • Success rate(10 minutes)
  • Injury rate(30 minutes)