Clinical Comparison of Silicone Hydrogel and HEMA-based Daily Disposable Contact Lenses

CIBA VISION0 个研究点目标入组 40 人开始时间: 2011年5月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
40
主要终点
Corrected Distance Monocular Visual Measurement Reported as Visual Acuity (VA)

研究概览

简要总结

The purpose of this trial was to compare the performance of an investigational daily disposable contact lens to a commercially available daily disposable contact lens.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • Normal eyes with no use of ocular medications.
  • Be of legal age of consent and sign Informed Consent document. If under legal age of consent, legally authorized representative must sign Informed Consent document and subject must sign Assent document.
  • Willing and able to wear spherical contact lenses for protocol-specified timeframe within the available range of powers (-1.00 D to -6.00D in 0.25D steps).
  • Visual acuity with study lenses 20/25 or better.
  • Cylinder less than or equal to 0.75 D.
  • Currently wearing daily disposable lenses.
  • Other protocol-defined inclusion criteria may apply.

排除标准

  • Anterior segment infection, inflammation, or abnormality.
  • Any active anterior segment ocular disease that would contraindicate contact lens wear.
  • Any use of systemic medications for which contact lens wear could be contraindicated as determined by the investigator.
  • History of refractive surgery or irregular cornea.
  • Eye injury within twelve weeks immediately prior to enrollment for this trial.
  • Currently enrolled in any clinical trial.
  • Other protocol-defined exclusion criteria may apply.

结局指标

主要结局

Corrected Distance Monocular Visual Measurement Reported as Visual Acuity (VA)

时间窗: 1 week of wear, replacing lenses daily

As tested for each eye individually while wearing study lenses. VA was measured using a Snellen chart, which was converted into logMAR units (logarithm of the minimum angle of resolution). A 20/20 Snellen acuity equated to a logMAR acuity of 0.0 and was considered normal distance eyesight. Positive logMAR values indicated poorer vision, and negative values denoted better visual acuity.

Overall Vision Quality

时间窗: 1 week of wear, replacing lenses daily

As interpreted by the participant and recorded on a questionnaire as a single, retrospective evaluation of 1 week of wear time. Overall vision quality was evaluated binocularly and rated on a 10-point scale, with 1 being poor and 10 being excellent.

Overall Comfort

时间窗: 1 week of wear, replacing lenses daily

As interpreted by the participant and recorded on a questionnaire as a single, retrospective evaluation of 1 week of wear time. Overall comfort was evaluated binocularly and rated on a 10-point scale, with 1 being poor and 10 being excellent.

Overall Handling

时间窗: 1 week of wear, replacing lenses daily

As interpreted by the participant and recorded on a questionnaire as a single, retrospective evaluation of 1 week of wear time. Overall handling was evaluated binocularly and rated on a 10-point scale, with 1 being difficult and 10 being easy.

次要结局

  • Overall Lens Fit(1 week of wear, replacing lenses daily)