MedPath

Pressure Gradient for Venous Return in Predicting Fluid Responsiveness in Patients Undergoing Laparoscopic Surgery

Conditions
Fluid Responsiveness
Registration Number
NCT04030221
Lead Sponsor
Second Affiliated Hospital, School of Medicine, Zhejiang University
Brief Summary

Surgical patients, especially those with insufficient blood volume and hypotension, often need fluid therapy. However, there is still a lack of simple and reliable indicators for judging transfusion responsiveness in some types of surgery. Previous studies have shown that Pressure Gradient for Venous Return (PVR) can be used to guide infusion. Thus, our aim is to explore the relationship between PVR and liquid reactivity.

Detailed Description

Fluid resuscitation is one of the key issues in the management of surgery and anesthesia. Fluid infusion test is a method to determine patients' reactivity to liquid therapy. The commonly used Stroke Volume Variation (SVV) and Pulse Pressure Variation (PPV) are good predictors of fluid responsiveness, but they are not suitable for operations with increased intra-abdominal pressure, such as laparoscopy surgery. Some studies have shown that Pressure Gradient for Venous Return (PVR) may has the same effect as PPV/SVV in predicting fluid responsiveness (FR). In the case that PPV/SVV cannot be used, PVR may be used alternatively. Therefore, our aim is to explore the relationship between the changes of PVR and fluid responsiveness during liquid infusion and to determine relevant parameters.

We will choose patients planed to receive laparoscopic surgery and general anesthesia, especially the patients with gastrointestinal tumors because of generally long operation time and much infusion volume. In our hospital, these patients will routinely indwelled arterial catheters and deep venous catheters during the operation. The former is mainly used to monitor direct arterial pressure, and the latter is used for fluid infusion.Through the above two pathways, we can collect the hemodynamic parameters of patients, and then establish the relationship between PVR and FR.

In our study, a good FR was defined as a 10% increase in cardiac index (CI) after fluid infusion, and PVR is calculated by a special formula based on some specific parameters of hemodynamics.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
40
Inclusion Criteria
  • patients undergoing laparoscopic surgery and general anesthesia
Exclusion Criteria
  • cardiac insufficiency; severe arrhythmias; patients using intra-aortic balloon pump; use of left ventricular assist devices; spasm of peripheral arteries caused by some factor

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
hemodynamic parametersAt enrollment

direct arterial pressure including systolic, diastolic and mean arterial pressure; central venous pressure.These data are collected continuously and dynamically.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

The second affiliated hospital of Zhejiang University

🇨🇳

Hangzhou, Zhejiang, China

© Copyright 2025. All Rights Reserved by MedPath