Contrast-enhanced Ultrasound for Follow-up After Radiofrequency Ablation of Renal Lesions: a Prospective, Blinded Study
试验速览
- 阶段
- 不适用
- 入组人数
- 30
- 试验地点
- 2
- 主要终点
- Sensitivity value of CEUS for tumour recurrence and by comparing to the standard CT/MRI.
研究概览
简要总结
Radiofrequency ablation (RFA) is an increasingly popular therapy option for treating small kidney cancer, especially for patients who are not ideal candidates for traditional surgery. Currently, follow-up after this procedure involves the patient having several CT scans (or MRI scans in some cases) over time to monitor for possible cancer recurrence. However, there are risks associated with the radiation exposure from CT scans and other risks, such as adverse events from the contrast media used in these scans. This study will therefore investigate whether a different technique, contrast-enhanced ultrasound (CEUS), can be an effective tool for follow-up monitoring of kidney cancer patients who have undergone RFA by comparing the results of their standard follow-up CT scans (or MRIs if applicable) with the results of CEUS. If CEUS is found to be just as effective as CT scans or MRIs in detecting kidney cancer recurrence, this technique could potentially become the new standard of care for follow-up.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Screening
- 盲法
- None
盲法说明
The radiologist is blinded to either CEUS or CT/MRI.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •at least 18 years of age and capable of giving informed consent
- •patient undergoing CT of MRI for monitoring of renal lesions after radiofrequency ablation
排除标准
- •pregnant patients
- •patients with allergies to iodinated contrast agents
- •patients with pulmonary hypertension, right-to-left cardiac shunts, or unstable cardiopulmonary disease (these are absolute or relative contraindications to the use of the ultrasound contrast agent, perflutren lipid microsphere)
结局指标
主要结局
Sensitivity value of CEUS for tumour recurrence and by comparing to the standard CT/MRI.
时间窗: 24 months post radiofrequency ablation procedure.
The accuracy of contrast-enhanced ultrasound in monitoring renal lesions post-radiofrequency ablation will be assessed through sensitivity, specificity, and positive predictive value of CEUS for tumour recurrence and by comparing to the standard CT/ MRI.
次要结局
- Quality of life data(24 months post radiofrequency ablation)
研究者
Anil Kapoor
MD, FRCSC
St. Joseph's Healthcare Hamilton
