跳至主要内容
临床试验/NCT05161884
NCT05161884招募中不适用

Validation of a Non-invasive Assessment of Central Venous Oxygen Saturation by Using Magnetic Resonance Imaging

German Heart Institute1 个研究点 分布在 1 个国家目标入组 135 人开始时间: 2021年4月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
135
试验地点
1
主要终点
oxygenation within the blood measured with MRI versus catherization

研究概览

简要总结

BOLD measured with MRI may be a useful noninvasive method for the assessment of right ventricular O2 saturation. A validation of this method against right heart catheterization has not been fully performed. Whether the method may have a diagnostic and prognostic role in chronic heart failure patients is unclear.

详细描述

Measurement of blood oxygen saturation (O2 saturation) is essential for the clinical evaluation of patients with cardiovascular disease, heart failure, and pulmonary disease. With the introduction of the right heart catheter, measurements of O2 saturation in the right heart, venae cavae, and pulmonary artery became readily available and have thus contributed significantly to our hemodynamic understanding of congenital and acquired heart disease. Furthermore, the introduction of a pulmonary artery catheter, which can be implanted within minutes at the bedside, allows better monitoring for critically ill patients in the intensive care unit. In acquired heart disease, O2 saturation provides important information about systemic oxygen delivery and consumption, making it essential for evaluating heart failure patients and patients with pulmonary arterial hypertension. Nevertheless, invasive catheter implantation is associated with not insignificant risks of complications and a noninvasive method has not yet been established.

The blood oxygen level-dependent (BOLD) effect has been established in recent years as an effective method to noninvasively measure O2 saturation using T2 magnetic resonance imaging (T2-MRI). BOLD effect-based oximetry has been found to provide noninvasive information about both blood oxygenation, myocardial oxygenation, and skeletal muscle oxygenation using MRI. The principle underlying this technique exploits the dependence of the T2- relaxation time on the oxygenation of hemoglobin, as well as the different magnetic properties of hemoglobin in the oxygenated and deoxygenated states. To establish the mathematical relationship between the T2 relaxation time of whole blood and O2 saturation, a Luz-Meiboom (L-M) model describing the transverse (T2) relaxation arising from the transfer of protons between a protein and a water solution was proposed. The application of this model has improved the "classical" BOLD sequences, which were only measurable in static tissue (myocardium), minimizing the large estimation variability in flows (ventricles and vessels), allowing a more quantitative measurement. With the increasing number of patients receiving transcatheter aortic valve implantation (TAVI) as well as being diagnosed with atypical pulmonary hypertension, a large number of patients with relevant comorbidities require invasive hemodynamic evaluation. Simultaneous evaluation of central venous SO2 (ScvO2) and cardiac function is highly desirable and could allow noninvasive staging of frail high-risk patients. The first pilot clinical study of this concept was recently published.

The first aim of the investigators is to determine the precision of non-invasive O2 saturation measurement using BOLD-T2-MRI in contrast to invasive O2 saturation measurement using a right heart catheter in patients.

The secondary objective of the study is to investigate the role of BOLD measurements as a diagnostic test in patients with dyspnea at presentation, at least NYHA class 2 and an indication for cardio MRI. In these patients, BOLD measurements will be performed both at rest and during exercise. A sensitivity analysis will be performed to determine the diagnostic value of BOLD measurements in different patient populations.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age > 18 years Ability to follow the study according to study protocol General ability to consent Presence of a written consent of the study participant Patients with a clinical indication for right heart catheterization

排除标准

  • Age <18 years. Pregnancy (for women of childbearing age, a pregnancy test is performed if pregnancy is possible) or breastfeeding.
  • Any condition that interferes with informed decision making General MRI exclusion criteria (pacemaker, defibrillator, intracranial aneurysm clips, metallic foreign bodies in the eyes) Any MRI exclusion criteria not listed here as determined by the performing MRI laboratory.
  • Hemodynamically unstable patients (heart rate < 50/min, systolic blood pressure < 90 mmHg, circulatory support devices: IABP, Impella) Complex supra- or ventricular arrhythmia occurring at rest or on exertion Right ventricular thrombus Recent pulmonary embolism Pulmonary instability (oxygen depletion or peripheral oxygen saturation <90%) Chronic lung disease (FEV< 35% on spirometry) Claustrophobia Sensorineural hearing loss from 30 dB and tinnitus

结局指标

主要结局

oxygenation within the blood measured with MRI versus catherization

时间窗: 1 Year

Comparison of the accuracy of BOLD MRI versus right heart catheterization (RHC)

differences in oxygenation within different heart failure groups

时间窗: 1 Year

Analysis of the sensitivity of BOLD measurements as a new diagnostic method for dyspnea at first presentation for various clinical applications

次要结局

未报告次要终点

研究者

发起方
German Heart Institute
申办方类型
Other
责任方
Principal Investigator
主要研究者

Sebastian Kelle

Head of Cardiac MRI

German Heart Institute

研究点 (1)

Loading locations...

相似试验