Reference Diameter and Characteristics of Distal Radial Artery by Ultrasonographic Assessement in Korean Patients

Wonju Severance Christian Hospital1 个研究点 分布在 1 个国家目标入组 1,162 人开始时间: 2017年7月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
1,162
试验地点
1
主要终点
The diameter of distal radial artery

研究概览

简要总结

Radial access is recommended as the standard approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI) based on the evidence in which RA reduced mortality and bleeding events compared with femoral access. Recently, the use of distal radial artery (DRA) is rapidly increasing in accordance with the publication of several studies that have shown easy hemostasis, reduced bleeding complications and low arterial occlusion rate via distal radial approach. However, the diameter of DRA is relatively smaller than radial artery (RA) which can limit the widespread use of this access route. Regarding the size discrepancy, there is a lack of evidence to guide which patients are acceptable or not for CAG and PCI. Therefore, the main purpose of this study was to provide the reference diameter of DRA using ultrasonography in Korean patients. The clinical predictors for small DRA also were evaluated.

详细描述

Radial access is recommended as the standard approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI) based on the evidence in which RA reduced mortality and bleeding events compared with femoral access. Recently, the use of distal radial artery (DRA) is rapidly increasing in accordance with the publication of several studies that have shown easy hemostasis, reduced bleeding complications and low arterial occlusion rate via distal radial approach. However, the diameter of DRA is relatively smaller than radial artery (RA) which can limit the widespread use of this access route. Regarding the size discrepancy, there is a lack of evidence to guide which patients are acceptable or not for CAG and PCI. Therefore, the main purpose of this study was to provide the reference diameter of DRA using ultrasonography in Korean patients. The clinical predictors for small DRA also were evaluated.

Assessment of arterial diameter by ultasonography Patients were lying on the bed with relaxation in an quiet room. The outer diameters of both DRA and RA were assessed by a perpendicular angle using a linear ultrasound probe (3-4-10.8 MHz) and the average values were recorded. The diameter of RA was measured from 2-3 cm above wrist crease. Anatomical landmark for the measurement of DRA was the bony surface area just distal space from extensor pollicis longus tendon in which the DRA was best palpable then runs down between the first metacarpal and second metacarpal bone (just out of anatomical snuffbox area)

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Retrospective

入排标准

年龄范围
20 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients planned to perform transthoracic echocardiography with arterial ultrasonography

排除标准

  • Age under 20-year
  • Poor image quality
  • repeated measurement

结局指标

主要结局

The diameter of distal radial artery

时间窗: Through ultrasonographic evaluation (within 1 hour)

Mean diameter of distal radial artery on both left and right hand

次要结局

  • The diameter of radial artery(Through ultrasonographic evaluation (within 1 hour))
  • Predictor for small distal radial artery(Through ultrasonographic evaluation (within 1 hour))
  • Arterial diameter index(Through ultrasonographic evaluation (within 1 hour))
  • Proportion of small distal radial artery(Through ultrasonographic evaluation (within 1 hour))

研究者

发起方
Wonju Severance Christian Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Jun-Won Lee

Associate professor

Wonju Severance Christian Hospital