Skip to main content
Clinical Trials/NCT00388570
NCT00388570
Completed
Not Applicable

A Multicenter, Device Randomized, Open-label Prospective Single-cohort Study of Monitoring Exhaled NO in Symptomatic Asthmatic Adults and Children During Anti-inflammatory Treatment

Aerocrine AB2 sites in 2 countries151 target enrollmentOctober 2006
ConditionsAsthma

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Asthma
Sponsor
Aerocrine AB
Enrollment
151
Locations
2
Primary Endpoint
The primary analysis variable will be the percent change in FENO measured with
Status
Completed
Last Updated
14 years ago

Overview

Brief Summary

The purpose of this study is to demonstrate substantial equivalence between two medical devices which measure nitric oxide in exhaled breath, NIOX MINO® and NIOX® in Symptomatic Asthmatic Adults and Children.

Detailed Description

Asthma is a chronic inflammatory disorder of the airways. Chronically inflamed airways are hyperresponsive; they become obstructed and airflow is limited (by bronchoconstriction, mucus plugs, and increased inflammation) when airways are exposed to various risk factors. Asthma causes recurring episodes of wheezing, breathlessness, chest tightness, and coughing particularly at night or in the early morning. NO is an important endogenous regulatory molecule that is widely distributed throughout the body. The detection of NO in exhaled air was first reported in 1991, and, soon after it was shown that the levels NO in exhaled air are elevated in patients with asthma. There is now much evidence showing that measurement of the concentration of NO in exhaled air offers a useful non-invasive method of assessing inflammatory airway disease. Exhaled NO is not increased during bronchospasm unless there is coexisting inflammation. Exhaled NO may have a valuable role in differentiating between the inflammatory and bronchospastic components of clinical asthma, and is also useful for guiding the therapeutic use of steroids and other anti-inflammatory agents. A study on asthmatics and non-asthmatics subjects has shown that substantial equivalence exists between the stationary device NIOX® and the hand held device NIOX MINO® when comparing NO measurements, when similar conditions are considered and examinations are made as consistently as possible. In a study with the stationary device NIOX®, exhaled NO was measured before and after two weeks of inhaled corticosteroid treatment in unstable steroid-naïve adult and paediatric asthmatic subjects. The result was a 50.5% mean reduction of exhaled NO. The change in exhaled NO was also compared to change in standard asthma outcome measures, asthma symptoms and spirometry.

Registry
clinicaltrials.gov
Start Date
October 2006
End Date
July 2007
Last Updated
14 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
Aerocrine AB

Eligibility Criteria

Inclusion Criteria

  • Children, and adults.
  • A history of physician-diagnosed asthma or asthma diagnosed by a physician.
  • Spirometry performed parameters.
  • An increased FENO value.
  • Symptomatic asthma as defined on the Asthma Control Questionnaire® (ACQ).

Exclusion Criteria

  • Use of oral corticosteroids.
  • Use of intranasal corticosteroids.
  • Use of non-steroidal anti-asthma drugs.
  • Current serious conditions and/or therapies that are confounding factors.
  • Pregnancy.
  • Other significant respiratory diseases and/or cardiovascular diseases.
  • Current participation in another interventional clinical study.
  • Inability to comply with the study procedures, e.g. spirometry and FENO measurements according to standard procedures.
  • Unwillingness to sign informed consent and comply with treatment and visits.
  • Smoking within 6 months before the study, or a smoking history of \>10 pack years or an equivalent amount of other tobacco use.

Outcomes

Primary Outcomes

The primary analysis variable will be the percent change in FENO measured with

NIOX MINO® and NIOX® between Visit 1 to Visit 2.

Secondary Outcomes

  • Agreement between NIOX MINO® and NIOX® will be assessed by comparing
  • individual pair-wise FENO measurements from visit V1.
  • The change in FENO measured with NIOX MINO following corticosteroid therapy
  • in asthma will be compared with improvements in standard asthma outcome
  • measures (asthma symptoms and spirometry).
  • To investigate the inter-operator variability FENO measurements with
  • NIOX MINO in the same subject when different operators take FENO measurements. Three operator each takes two completed measurements in the same subject in a point of care setting.

Study Sites (2)

Loading locations...

Similar Trials