Investigation of Respiratory Motion-Corrected Cone-Beam CT and Intratreatment Gating Based on Electromagnetic Transponders to Reduce Target Position Uncertainty in Radiation Treatment of Lung Malignancies
试验速览
- 阶段
- 不适用
- 状态
- 进行中(未招募)
- 入组人数
- 17
- 试验地点
- 3
- 主要终点
- successful Calypso transponder implantation
研究概览
简要总结
The first purpose of this study is to test a new computer program that reduces the blurring in the cone-beam CT scan and helps the doctor to better locate the tumor. The investigators want to find out what effects, good and/or bad, that this has on the patient and the way we treat the cancer in the lungs.
The second purpose of this study is to test how well this computer program tracks markers in the images, compared to using radio signals to follow the markers.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Histologic proof of malignancy suitable for thoracic radiation therapy
- •Patient is planning to undergo radiation therapy for primary or recurrent malignancies of the lung or metastatic malignancies to the lung.
- •Age ≥ 18 years old
- •Karnofsky Performance Status ≥ 60%
- •At least part of the tumor must be visible as observed in a diagnostic or planning CT.
- •Able to have bronchoscopic placement of Calypso transponders as confirmed on a recent (within the past 8 weeks) CT scan.
排除标准
- •Patients with clinically significant active infections.
- •Bronchiectasis in the region of the intended implantation.
- •History of hypersensitivity to nickel.
- •Other medical condition or laboratory value that would, at the discretion of the investigator, preclude the patient from participation in this clinical study.
- •Deemed unable to safely undergo or tolerate flexible bronchoscopy as per institutional guidelines
- •Unable to tolerate anesthesia or sedation
- •Enrolled in any other clinical studies the investigator believes to be in conflict with this investigation.
- •Female patients who are pregnant or nursing
- •Exclusion criteria for Calypso transponders:
- •Implants in the chest region that contain metal or conductive materials (e.g., metal implants, rods, or plates) which Calypso Medical considers will interfere with the Calypso System's electromagnetic localization.
- •Active implanted devices, such as pacemakers, defibrillators, and drug infusion pumps since the effects of the Calypso System operation on these devices are unknown.
- •Patients whose lung tumors are being monitored by MR imaging as part of standard clinical care. Implantation of transponders will degrade MR images.
- •Posterior lesions that would be >19 cm distance from Calypso detector plate.
研究组 & 干预措施
Patients with lung cancer
Physician evaluation of patient setup accuracy will be performed using all available images and adjustments will be made as per standard practice. In addition, a respiration motion-corrected CBCT (daily for SBRT, weekly for standard fractionation) will be used to confirm the accuracy of Calypso-based setup. Patients will return for follow up at 3,6, 9, 12, 15, 18, 21 and 24 months (+/- 4 weeks) following completion of radiation therapy. The following assessments will be performed at these visits: history and physical exam, diagnostic CT chest, and toxicity assessment.
干预措施: Bronchoscopic Implantation (Procedure)
Patients with lung cancer
Physician evaluation of patient setup accuracy will be performed using all available images and adjustments will be made as per standard practice. In addition, a respiration motion-corrected CBCT (daily for SBRT, weekly for standard fractionation) will be used to confirm the accuracy of Calypso-based setup. Patients will return for follow up at 3,6, 9, 12, 15, 18, 21 and 24 months (+/- 4 weeks) following completion of radiation therapy. The following assessments will be performed at these visits: history and physical exam, diagnostic CT chest, and toxicity assessment.
干预措施: Cone-Beam CT-Guided (Device)
Patients with lung cancer
Physician evaluation of patient setup accuracy will be performed using all available images and adjustments will be made as per standard practice. In addition, a respiration motion-corrected CBCT (daily for SBRT, weekly for standard fractionation) will be used to confirm the accuracy of Calypso-based setup. Patients will return for follow up at 3,6, 9, 12, 15, 18, 21 and 24 months (+/- 4 weeks) following completion of radiation therapy. The following assessments will be performed at these visits: history and physical exam, diagnostic CT chest, and toxicity assessment.
干预措施: stereotactic body radiation treatments (Radiation)
结局指标
主要结局
successful Calypso transponder implantation
时间窗: 1 year
The RapidTrack algorithm will be considered successful if the centroid position of the Calypso transponders, as determined by the RapidTrack algorithm, are within 2 mm of the positions determined by the Calypso system 95% of the time.
次要结局
未报告次要终点