跳至主要内容
临床试验/NCT02118103
NCT02118103Unknown不适用

The Impact of Spinal Manipulation on Lower Extremity Motor Control in Lumbar Spinal Stenosis Patients: a Single-blind Randomized Before-after Trial

University of Manitoba1 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2014年5月最近更新:
适应症

试验速览

阶段
不适用
入组人数
24
试验地点
1
主要终点
Spatial Endpoint Accuracy

研究概览

简要总结

The objectives of the proposed research are to quantify the impact on motor performance of a single SM intervention on surgical waitlist patients with degenerative Lumbar Spinal Stenosis (LSS) using a recently established lower extremity movement task: 1) using alterable levels of task difficulty that is resistant to learning and 2) using measurement of movement kinematics.

详细描述

METHODOLOGY:

A non-surgical spine care clinician, (physical therapist or chiropractor) who is not the principal investigator, will rule out, through physical examination and history, any further contraindications to lumbar spinal manipulation (SM) prior to intervention. The physical examination will consist of orthopedic tests typically used in clinical practice prior to spinal manipulation intervention. No intervention will be delivered by the principal investigator.

Upon arrival participants will provide consent to the research assistants by filling out the Research Participant Information and Consent Form. They will then complete a battery of questionnaire based outcome measures including a 2 quadruple numeric rating scales (QNRS), one for each left, and right leg pain, the Swiss Spinal Stenosis score (SSS)(Stucki, Daltroy, Liang et al 1996) and the Waterloo Footededness Questionnaire - revised (WFQ-R) (Elias, Bryden, Bulman-Fleming 1998) on a computer. The width and length of the distal pad of the great toe will be measured bilaterally.

Apparatus:

A 23" projected image will be positioned lengthwise in front of the participant on a surface, parallel to the floor but facing the ceiling, on a custom built support frame and platform. A microswitch will be mounted in the support frame platform on the edge proximal to the participant and will serve as the home position. Custom software (E-prime, v 2.0 Psychology Software Tools Inc., Sharpsburg, PA) will be used to generate the projected images, to track switch initiated timing, and trigger/synchronize 3-dimensional movement recording. An infrared emitting diode (IRED), (Northern Digital, Waterloo, ON) will be mounted to the distal aspect of the great toe using a custom removable brace.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Investigator)

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Confirmed Lumbar Spinal Stenosis Diagnosis (by diagnostic imaging and clinical testing/history from a spine surgeon)

排除标准

  • Prior surgery to address Spinal Stenosis
  • Presence of trauma, tumor, or infectious processes that are contraindications to spinal manipulation

结局指标

主要结局

Spatial Endpoint Accuracy

时间窗: same 1 day, during foot pointing tasks

Spatial endpoint accuracy will be the distance from the center of the toe pad touch down to the center of the target.

Active Lumbar Range of Motion (ROM)

时间窗: same 1 day, prior to and following intervention or non-intervention

Active lumbar ROM (in degrees) will include flexion, extension, bilateral lateral flexion and bilateral rotation. It will be compared between groups, both prior to and following intervention (or NI).

Movement Time

时间窗: same 1 day, during foot pointing tasks

Movement time (milliseconds) will be defined as the time between toe lift off from the home position and contact with the target.

Displacement

时间窗: same 1 day, during foot pointing tasks

measured in millimeters

Time to Peak Velocity

时间窗: same 1 day, during foot pointing tasks

Time to peak velocity will be defined as the time point in ms at which the great toe reached peak velocity in the plane of movement toward the target.

Reaction Time

时间窗: same 1 day, during foot pointing tasks

Reaction time (milliseconds) will be defined as the time between the presentation of the target, to the lift off from the home position of the toe reaching toward the target.

Peak Velocity

时间窗: same 1 day, during foot pointing tasks

Peak velocity will be defined as the point of greatest velocity (meters per second) of the great toe in the plane of movement toward the target.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Dr. Steven Passmore

Steven Passmore, DC, PhD

University of Manitoba

研究点 (1)

Loading locations...

相似试验