NCT01420900
Completed
Not Applicable
Ceramic-on-Ceramic Total Hip Arthroplasty and Squeaking: A Prospective, Blinded, Randomized Clinical Trial of Influence of Component Design
ConditionsHip Arthrosis
Overview
- Phase
- Not Applicable
- Intervention
- Not specified
- Conditions
- Hip Arthrosis
- Sponsor
- Vejle Hospital
- Enrollment
- 204
- Locations
- 1
- Primary Endpoint
- All noises from THA
- Status
- Completed
- Last Updated
- 8 years ago
Overview
Brief Summary
The investigators want to examine if specific acetabular liner designs can be a contributing factor to audible squeaking associated with CoC bearings. The aim of the present study is to compare two different designed and well documented acetabular component systems with reference to squeaking and other noises from the hip.
Investigators
Claus Varnum
MD
Vejle Hospital
Eligibility Criteria
Inclusion Criteria
- •All patients scheduled for uncemented THA under the age of 65 years.
Exclusion Criteria
- •Patients with the following diagnoses of the hip: Recent femoral fracture, sequelae from older femoral fracture, acetabular fracture, and traumatic dislocation of the hip.
- •Patients without ability to give informed consent and/or willingness to participate in the follow-up protocol.
- •Severely impaired level of function due to other physical deficiencies than the hip.
- •Mental disability that could impair a patient's decision-making capability of giving informed consent and not enabling valid data collection.
- •Earlier primary THA or revision THA in the contralateral hip.
- •Pathology requiring another prosthesis concept than the below mentioned.
- •Body mass index greater than 35.
Outcomes
Primary Outcomes
All noises from THA
Time Frame: One year
Secondary Outcomes
- Life quality(One year)
Study Sites (1)
Loading locations...
Similar Trials
Completed
Not Applicable
28 mm Ceramic-on-Ceramic Acetabular Cup Total Hip Replacement StudyJoint DiseasesNCT00208507DePuy Orthopaedics264
Completed
Not Applicable
Squeaking in Ceramic-on-Ceramic Total Hip Arthroplasty Using Delta TT CupOsteoarthritis, HipOsteonecrosis of Femoral HeadFemoral Neck FracturesRheumatoid Arthritis of HipPosttraumatic ArthropathyNCT04594564Seoul National University Hospital270
Terminated
Phase 4
Ceramic on Metal Total Hip Replacement System Multi-Center,Investigational Device Exemption Clinical TrialTotal Hip Replacement SystemNCT00820443MicroPort Orthopedics Inc.253
Completed
Phase 4
Ceramic-on-Ceramic Versus Ceramic-on-HXLPE THAOsteoarthritis, HipAvascular Necrosis of the Femoral HeadArthropathy of HipHip ArthrNCT03639532Ewha Womans University148
Completed
Not Applicable
Effect of Cemented Stem Design on Periprosthetic Bone Mass Following Primary Total Hip ArthroplastyOsteoarthritisNCT00293605Sheffield Teaching Hospitals NHS Foundation Trust120