MedPath

Pivotal Study of the Medtronic Axys EX Rotational Atherectomy System

Not Applicable
Withdrawn
Conditions
Peripheral Arterial Disease
Interventions
Device: Axys EX device
Registration Number
NCT04282161
Lead Sponsor
Medtronic Endovascular
Brief Summary

The primary objective is to demonstrate the safety and effectiveness of the Axys EX rotational atherectomy system in subjects with peripheral arterial disease who have de novo or non-stented restenotic obstructive lesions in the peripheral vasculature of the lower limbs.

Detailed Description

Not available

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  1. Rutherford Clinical Category (RCC) Score of 2 - 5

  2. Willing and capable of complying with all follow-up evaluations at the specified times

  3. Age ≥ 18 years old

  4. Provides written informed consent prior to study specific procedures

  5. Completed Ankle/Brachial Index (ABI) (or Toe/Brachial Index [TBI]) prior to index procedure (up to 60 days prior)

    Angiographic Inclusion Criteria:

  6. Evidence of ≥ 70% stenosis or occlusion in the peripheral vasculature of the target vessel, confirmed by angiography

  7. Target lesion present in a single limb that consists of a single de novo or non-stented restenotic lesion, or qualifies as a tandem or combination lesion per the definitions below:

    1. Tandem (adjacent) Lesion: Lesions present in the same target vessel that can be treated as one single lesion and is separated by an angiographic normal vessel ≤3 cm at any point. Multiple points of separation can be present in single lesion treatment if no single point of separation is > 3 cm
    2. Combination Lesion: A single lesion that is not completely occluded but includes a segment of complete occlusion anywhere along the length
  8. Exchangeable guidewire must cross target lesion within the lumen

  9. Total target lesion length is ≥ 20 mm and ≤ 200mm

  10. Reference vessel diameter (RVD) is ≥ 2.0 mm and ≤ 5.0 mm

  11. Identifiable distal target vessel which upon completion of the intervention is anticipated to provide reconstitution of blood flow to the foot. Angiographic evidence of adequate distal runoff through the foot (at least one native calf vessel [posterior tibial, anterior tibial, or peroneal artery] is patent, defined as < 50% stenosed)

  12. Multiple lesions in the target limb (including the target lesion and non-target lesions) may be treated if all of the following applies:

    1. Non-target lesion(s) must be located proximal to the target lesion
    2. Non-target lesion(s) must be successfully treated (defined as optimally treated [e.g. no untreated arterial dissections or perforation present]) by standard endovascular procedures prior to initiation of treatment of the target lesion
    3. Non-target lesions treated prior to target lesion cannot be treated with rotational, orbital or laser atherectomy
    4. Non-target lesion(s) may be located in separate vascular beds (i.e., iliac,femoropopliteal, tibial) or multiple tibial vascular beds (i.e., anterior tibial, posterior tibial, tibioperoneal trunk/peroneal). (Note: Only one tibial vessel may be identified as the target vessel with the target lesion.)
    5. Only one lesion per the above definitions may be treated as the target lesion with the Axys EX device

    General

Exclusion Criteria
  1. Has one or more of the contraindications listed in the Axys EX Rotational Atherectomy System's IFU

  2. Contraindication or known untreated allergy to antiplatelet therapy, anticoagulants, thrombolytic drugs, or any other drug anticipated to be used

  3. Hypersensitivity to contrast material that cannot be adequately pretreated

  4. Known uncontrollable hypercoagulable condition or refuses blood transfusion

  5. Life expectancy of less than 12 months

  6. Surgical (requiring hospitalization) or endovascular intervention of the target limb within 30 days prior to the index procedure

  7. Planned surgical intervention or endovascular procedure within 30 days after the index procedure

  8. Currently participating in an investigational drug or another device study that may clinically interfere with the study endpoints

  9. Other co-morbid condition(s) that in the judgment of the physician precludes safe percutaneous intervention

  10. If a previous peripheral bypass affecting the target limb is present, the bypass must be patent and the target lesion cannot be present in the peripheral bypass artery

  11. Impaired renal function (defined as GFR < 30 mL/min) or on dialysis

  12. Recent myocardial infarction or stroke ≤ 30 days prior to the index procedure

  13. Previous or planned amputation above the metatarsal line on the target limb

  14. Patient belongs to a vulnerable population per investigator's judgment or patient has any kind of disorder that compromises his/her ability to give written informed consent and/or to comply with study procedures. Patient must be able to consent for themselves

  15. Patient is pregnant (female patients of child-bearing potential must have a pregnancy test done within 7 days prior to the index procedure)

    Angiographic Exclusion Criteria:

  16. Noted thrombus at the point of the intended target lesion

  17. In-stent restenosis of the target lesion

  18. Aneurysmal target vessel

  19. Hemodynamic significant stenosis or occlusion of inflow tract that has not been revascularized prior to treatment of the target vessel

  20. Perforation, flow limiting dissection or other injury of the target vessel requiring surgical intervention prior to enrollment

  21. Disease that precludes safe advancement of the Axys EX device to the target lesion

  22. Need to treat a lesion distal to the target index lesion

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Axys EX deviceAxys EX device-
Primary Outcome Measures
NameTimeMethod
Primary EffectivenessDuring procedure

Change in percent stenosis in the treatment vessel. Percent stenosis is defined as native vessel diameter as measured at the narrowest point of the lesion divided by the estimated native vessel diameter at that location.

Primary Safety30-Days

Major Adverse Events (MAEs) at 30 Days post-procedure defined as freedom from clinically-driven target lesion revascularization (CD-TLR), major unplanned amputation of the treated limb, or all-cause mortality.

Secondary Outcome Measures
NameTimeMethod
Provisional Stent RateDuring Procedure
Rate of Target Lesion Revascularization (TLR)6 and 12-Months

Any re-intervention at the target lesion

Major Adverse Events (MAEs)12-Months

Defined as freedom from clinically-driven target vessel revascularization (CD-TVR), major unplanned amputation of the treated limb, thrombosis at the target lesion site, or all-cause mortality

Amputation-Free Survival12-Months

Defined as freedom from a major, unplanned amputation of the target limb through the 12 month visit

Technical SuccessDuring Procedure

Defined as the ability of the Axys EX device to successfully traverse/cross the entire intended length of the target lesion

Rate of Target Vessel Revascularization (TVR)6 and 12-Months

Any re-intervention within the target vessel

Flow Limiting DissectionDuring Procedure

Target lesion flow limiting dissection (D or greater) rate after adjunctive therapy

Walking Distance30-Days, 6 and 12-Months

6-Minute Walking Test

Ankle/brachial index (ABI) or toe/brachial index (TBI)30-Days, 6 and 12-Months
Procedural SuccessDuring Procedure

Defined as ≤ 30% residual stenosis following use of the Axys EX device and adjunctive therapy as measured by angiography and determined by the angiographic core laboratory

Primary Patency as determined by Duplex Ultrasound (DUS)6 and 12-Months

1. For subjects with a target lesion in the femoropopliteal region (above the knee \[ATK\]) through the level of popliteal segment P3 (below the knee popliteal artery from the center of the knee joint space to the origin of anterior tibial artery), primary patency is defined as freedom from core laboratory-assessed restenosis (DUS PSVR ≤2.4) and CD-TLR (adjudicated by a Clinical Events Committee)

2. For subjects with a target lesion below the level of popliteal segment P3 (below the knee \[BTK\]), primary patency is defined as freedom from core laboratory-assessed absence of target lesion occlusion (no flow) as assessed by DUS and CD-TLR (adjudicated by a Clinical Events Committee)

Quality of Life Assessment30-Days, 6 and 12-Months

EQ-5D questionnaire

Major Vessel Perforation30-Days

requiring surgical or endovascular repair within 30 days (adjudicated by a Clinical Events Committee) 6.

Walking Capacity30-Days, 6 and 12-Months

Walking Impairment Questionnaire (WIQ)

Rutherford clinical category (RCC)30-Days, 6 and 12-Months
Distal Embolization in Target Limb30-Days

Clinically significant distal embolization in target limb within 30 days defined as distal embolization requiring treatment by mechanical or pharmacologic means (other than a vasodilator) (adjudicated by a Clinical Events Committee)

© Copyright 2025. All Rights Reserved by MedPath