跳至主要内容
临床试验/NCT01331096
NCT01331096Unknown不适用

Tele-Anesthesia - Trans-Continental Anesthesia Compared to Standard Practice

Azienda Ospedaliero, Universitaria Pisana1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2011年3月最近更新:
适应症

试验速览

阶段
不适用
入组人数
200
试验地点
1
主要终点
Performance of closed-loop system for propofol administration, controlled remotely, compared with the performance of propofol manually administered to maintain in both case the level of hypnosis close to the BIS target.

研究概览

简要总结

Patients in Pisa will undergo thyroid gland surgery. In the protocol group anesthesia will be performed using an automated anesthesia delivery system; preoperative and intra-operative assessment of patients will be performed via video-conferencing from Montreal, which will also monitor and control anesthesia delivery via distant Internet connection - as supervision of functioning of the automated anesthesia delivery system. In the control group anesthesia will be performed in a standard fashion with manual control of the syringe pumps infusing anesthetics drugs.

The hypothesis is that Tele-anesthesia, considered as preoperative assessment and anesthetic control of an automated anesthesia delivery system is feasible and reliable via standard means of internet communication (distant control via virtual network) and performed as well or even better than manual control of the anesthetic drugs infusion.

研究设计

研究类型
Observational
时间视角
Prospective

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Elective patients
  • Patient scheduled for surgery under spinal anesthesia
  • Patients aged 18 to 85 years

排除标准

  • Unable to provide informed consent
  • Comatose patients
  • Patients with dementia
  • Allergy to Propofol

结局指标

主要结局

Performance of closed-loop system for propofol administration, controlled remotely, compared with the performance of propofol manually administered to maintain in both case the level of hypnosis close to the BIS target.

时间窗: 2 years

Hypnosis is monitored during the surgery according to the brain activity values provided by an objective monitoring parameter, called Bispectral Index (BIS). A BIS target of 45 is aimed trough the surgery. Performance of propofol hypnosis will be determined clinically by recording the % of sedation time during which the actual BIS is within 10% of the target BIS (excellent control), within 11 -20% (good control), between 21-30% (fair control) and beyond 30% of target (inadequate control).

次要结局

未报告次要终点

研究者

申办方类型
Other

研究点 (1)

Loading locations...

相似试验

Tele-Anesthesia - Trans-Continental Anesthesia... | 临床试验