临床试验/NCT07356505
NCT07356505招募中不适用

Efficacy and Safety of Micra AV2 Transcatheter Pacing System

Universitaire Ziekenhuizen KU Leuven0 个研究点目标入组 150 人开始时间: 2026年1月12日最近更新:

试验速览

阶段
不适用
状态
招募中
入组人数
150

研究概览

简要总结

A third generation, Micra AV2 is now available and proposes increased automaticity and improved AV synchrony algorithms based on computing model. The new algorithms permit the delivery of AV synchronous pacing, improving the automatic AV synchrony at faster heart rates between 80-100 bpm with a maximal upper tracking rate limit of 135 bpm (previously 115-120 bpm in the Micra AV1). Micra AV2 presents also a potential extended longevity of 15.6 years (increased by > 44% in comparison of Micra AV1). Up to now, no clinical study has evaluated the efficacy and safety of Micra AV2 in a real-world setting.

The focus of this study is to characterize chronic ambulatory AV synchrony in patients with high degree AV block and normal sinus rhythm implanted with a Micra AV2 as primary objective to evaluate AV synchrony during exercise as secondary objective.

详细描述

Prospective, single-arm, multi-centre clinical study to characterize the chronic efficacy and safety profile of CE approved and market released Micra AV2 A sample size of approximately 150 subjects implanted with a Micra AV2 is required to evaluate the different objectives. A minimal sample size of 50 subjects with persistent 3rd degree AVB and normal sinus node function is required to evaluate the ambulatory AV synchrony at 6-month follow-up.

Primary objective:

Characterize ambulatory AV synchrony in subjects with persistent third degree AV block and normal sinus node function at 6-month post Micra AV2 implant procedure

Secondary objective(s):

  1. Characterize the AV synchrony and device behaviour during exercise in subjects with persistent third degree AV block and normal sinus node function at 6-month post implant procedure
  2. Characterize the evolution of left ventricular function at 12-month post implant
  3. Evaluate the efficacy of the 'Atrial Sensing Setup' at the end of the implant procedure
  4. Long-term follow-up (3 years) to evaluate AV synchrony, need for system revision and complication rate including rate of pacing induced cardiomyopathy

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Voluntary written informed consent of the participant or their legally authorized representative has been obtained prior to any screening procedures
  • At least 18 years of age at the time of signing the Informed Consent Form (ICF)
  • Participant will be implanted with a Micra AV2 for an approved indication for use
  • Participant with a history of any type of high-degree AV block
  • Participant is willing and able to comply the study protocol

排除标准

  • Subject implanted with a Micra AV2 on a non-permanent basis (e.g. CIED infection)
  • Subject is pregnant (if required by local law, women of child-bearing potential must undergo a pregnancy test within seven days prior to Micra AV2 implant procedure)
  • Subject currently enrolled or planning to participate in a potentially confounding drug or device trial during the study.
  • 4. Subject meets any exclusion criteria required by local law (age or other)

研究者

申办方类型
Other
责任方
Sponsor