跳至主要内容
临床试验/NCT01375855
NCT01375855Unknown4 期

Late Incomplete Stent Apposition Evaluation II: Vascular Effects Evaluation After Polimer and No-polimer Based Coronary Artery Drug Eluting Stent Ilmplantation. An IVUS Based Study

Fundació Institut de Recerca de l'Hospital de la Santa Creu i Sant Pau2 个研究点 分布在 1 个国家目标入组 320 人开始时间: 2007年10月1日最近更新:
适应症

试验速览

阶段
4 期
发起方
入组人数
320
试验地点
2
主要终点
Intra coronary ultrasound analysis to verify stent malapposition at follow-up

研究概览

简要总结

Vascular effects evaluation after non-polimeric and polimeric paclitaxel stent implantation.In particular the investigators will use Taxus )as a polimeric stent)and Axxion (as a non-polimeirc)stent system. The investigators will look at late stent malapposition by means of intracoronary ultrasound imaging technique (IVUS) at baseline and 9 months follow-up. The investigators sought to compare the two stent types with the same drug to verify the polimer role. The polimer itself seems to provoke inflammation and hypersensibility if the arterial wall and it seems to be the base of a process of positive remodeling found at drug eluting stent implantation site.

This positive remodeling is the mechanism producing late stent malapposition which on its turn can determine stent thrombosis, as demonstrated by pathological studies. At the same time the investigators will study the incidence of clinical events like myocardial infarction, stent thrombosis, TLR and death along with the incidence of angiographic restenosis at 2 years follow up.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with coronary artery stenosis in one, two or three vessels, and with objective evidence of isquemia.
  • The stenosis must allow IVUS analisis, must be treatable with angioplasty with stent
  • Target Vessel diameter must be between 2.25- 4 mm with QCA.
  • Patients must sign informed consent
  • Patients and their physician must accept the angiographic follow-up

排除标准

  • 18 years old patients
  • SCA within the last 72 hours, or patients with CK twice over the upper normal limit
  • Pregnancy
  • Target vessel diameter < 2.25 or > 4 mm by QCA
  • Previous brakitherapy or DES in the target lesion
  • Restenotic lesion
  • -Allergy to aspirin, clopidogrel or ticlopidin
  • Patients enrolled in other studies or trials
  • By-pass graft lesions
  • Real bifurcationa lesions
  • Severe Renal insufficiency (creatinin clearance < 30 ml/min).
  • Severe Liver failure(GOT y GPT > 3 times the upper normal limit)
  • Life expectancy < 1 year because of other pathologies

结局指标

主要结局

Intra coronary ultrasound analysis to verify stent malapposition at follow-up

时间窗: 9 months

次要结局

  • Clinical events (myocardial infarction, TLR,at 1, 9, 12, 24 months follow-up:; Incidence of restenosis with QCA at 9 months follow-up Intimal hiperplasia measured by IVUS at 9 months follow-up; Stent Thrombosis.(9 months and 2 years)

研究者

发起方
Fundació Institut de Recerca de l'Hospital de la Santa Creu i Sant Pau
申办方类型
Other

研究点 (2)

Loading locations...

相似试验