跳至主要内容
临床试验/NCT03665818
NCT03665818已完成不适用

The Influence of Mandibular Advancement Device Treating OSAHS on Primary Prevention of Ischemic Stroke

Xuanwu Hospital, Beijing0 个研究点目标入组 100 人开始时间: 2016年7月9日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
100
主要终点
lowest Oxygen Saturation 1 in percentage

研究概览

简要总结

  1. The purpose of this study is to detect the differences of carotid atherosclerosis severity between patients with or without OSAHS(Obstructive Sleep Apnea and Hypopnea Syndrome) in a cross-sectional study in a large sample.
  2. Then a longitudinal control study is conducted to observe the progress of the carotid atherosclerosis by vascular ultrasonography and the occurrence of cerebrovascular events after the intervention of the oral appliance for treating OSAHS,and finally explore the feasibility of using oral appliance to treat OSAHS in primary prevention of ischemic stroke.

详细描述

  1. the relevance of OSAHS and carotid atherosclerosis Patients are distributed questionnaire and recruited from neurology clinic,vascular ultrasonography clinic of Xuanwu Hospital if they match the inclusion criteria. After initial screening, carotid atherosclerosis patients with skeptical OSAHS are sent to sleep center for polysomnography examination to determine the severity of OSAHS. At least 50 patients for mild, moderate, severe OSAHS each are recruited for OSAHS Group. At least 100 patients without snoring from questionnaire and without OSAHS after PSG screening are recruited for non OSAHS Group. Vascular ultrasonography examination for carotid are done for the two groups. Data of carotid vascular plaque from two groups are collected. Statistics are done to detect differences of carotid atherosclerosis severity between patients with and without OSAHS, also the severity of OSAHS.
  2. the relevance of the progress of carotid atherosclerosis and oral appliances intervention for treating OSAHS All carotid atherosclerosis patients with OSAHS are from patients of the first study. If they consent the treatment of oral appliances, they are recruited into this second study. At least 100 patients are recruited. They are divided into 2 groups by randomized block design by Evidence-based Medicine Center of Xuanwu Hospital. One group is oral appliance intervention group, the other group is no intervention group. The intervention group patients accept oral appliance treatment, and no intervention group patients do not accept OSAHS treatment. The two groups both accept anti-hypertension treatment or anti-diabetes treatment, or anti-hyperlipidemia treatment according to their own situation in neurology clinic.

At timepoint of initial time, one month after oral appliance treatment, one and a half year after oral appliance treatment, the intervention group should accept PSG(Polysomnography) examination to monitor the treatment of OSAHS.

At timepoint of initial time, one month after oral appliance treatment, one and a half year after oral appliance treatment, the two groups should accept breath holding test to monitor the cerebral vascular reserve.

At timepoint of initial time, one and a half year after oral appliance treatment, the two groups should accept carotid vascular ultrasonography examination to monitor the progress of carotid atherosclerosis.

Cerebrovascular events and death are recorded from initial time. Statistics are done to detect the influence of treatment of OSAHS on carotid atherosclerosis.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •diagnosed with atherosclerosis by vascular ultrasonography
  • •diagnosed with OSAHS by polysomnography

排除标准

  • •patients who have stroke already
  • •patients who can not wear oral appliances according to experiment requirements
  • •patients who have bad periodontal condition or teeth number less than 20

研究组 & 干预措施

Oral appliance intervention

Experimental

干预措施: oral appliance treatment (Device)

Without oral appliance intervention

No Intervention

结局指标

主要结局

lowest Oxygen Saturation 1 in percentage

时间窗: one month after oral appliance treatment

blood lowest oxygen saturation during the whole night

atherosclerosis plaque length 1 in internal carotid artery in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque length is distance from the beginning to the end of a separate plaque

apnea hypopnea events 0 in Times

时间窗: initial time when patients are recruited

apnea and hypopnea times per hour

longest apnea time 1 in Seconds

时间窗: one month after oral appliance treatment

longest apnea or hypopnea time

longest apnea time 0 in Seconds

时间窗: initial time when patients are recruited

longest apnea or hypopnea time

longest apnea time 2 in Seconds

时间窗: one and a half years after oral appliance treatment

longest apnea or hypopnea time

Blood oxygen saturation less than 90% of the total monitoring time percentage 1 in percentage

时间窗: one month after oral appliance treatment

Blood oxygen saturation less than 90% of the total monitoring time percentage

Blood oxygen saturation less than 90% of the total monitoring time percentage 2 in percentage

时间窗: one and a half years after oral appliance treatment

Blood oxygen saturation less than 90% of the total monitoring time percentage

atherosclerosis plaque thickness 0 in carotid bulb in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

atherosclerosis plaque length 0 in carotid bolb in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque length is distance from the beginning to the end of a separate plaque

Blood oxygen saturation less than 90% of the total monitoring time percentage 0 in percentage

时间窗: initial time when patients are recruited

Blood oxygen saturation less than 90% of the total monitoring time percentage

lowest Oxygen Saturation 2 in percentage

时间窗: one and a half years after oral appliance treatment

blood lowest oxygen saturation during the whole night

atherosclerosis plaque length 1 in common carotid artery in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque length is distance from the beginning to the end of a separate plaqu

atherosclerosis plaque thickness 0 in internal carotid artery in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

atherosclerosis plaque length 1 in carotid bolb in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque length is distance from the beginning to the end of a separate plaque

breath holding index 0 in percentage/seconds

时间窗: one and a half years after oral appliance treatment

breath holding index = (v2-v1)/v2\*100/t. v2 is average velocity of middle cerebral artery after breath holding, v1 is average velocity of middle cerebral artery before breath holding, t is time for breath holding.

End systolic velocity of internal carotid artery 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of internal carotid artery at the end of systolic period

End systolic velocity of carotid bulb 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of carotid bulb at the end of systolic period

end diastolic velocity of common carotid artery 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of common carotid artery at the end of diastolic period

apnea hypopnea events 1 in Times

时间窗: one month after oral appliance treatment

apnea and hypopnea times per hour

apnea hypopnea events 2 in Times

时间窗: one and a half years after oral appliance treatment

apnea and hypopnea times per hour

lowest Oxygen Saturation 0 in percentage

时间窗: initial time when patients are recruited

blood lowest oxygen saturation during the whole night

atherosclerosis plaque thickness 0 in common carotid artery in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

atherosclerosis plaque thickness 1 in carotid bulb in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

atherosclerosis plaque length 0 in internal carotid artery in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque length is distance from the beginning to the end of a separate plaque

atherosclerosis plaque thickness 1 in common carotid artery in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

atherosclerosis plaque length 0 in common carotid artery in milimetre

时间窗: initial time when patients are recruited

atherosclerosis plaque length is distance from the beginning to the end of a separate plaque

atherosclerosis plaque thickness 1 in internal carotid artery in milimetre

时间窗: one and a half years after oral appliance treatment

atherosclerosis plaque thickness is distance from the most convex point of plaque to carotid media

End systolic velocity of common carotid artery 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of common carotid artery at the end of systolic period

end diastolic velocity of common carotid artery 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of common carotid artery at the end of diastolic period

end diastolic velocity of internal carotid artery 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of internal carotid artery at the end of diastolic period

end diastolic velocity of carotid bulb 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of carotid bulb at the end of diastolic period

End systolic velocity of common carotid artery 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of common carotid artery at the end of systolic period

End systolic velocity of internal carotid artery 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of internal carotid artery at the end of systolic period

End systolic velocity of carotid bulb 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of carotid bulb at the end of systolic period

end diastolic velocity of carotid bulb 1 in cm/s

时间窗: one and a half years after oral appliance treatment

the velocity of carotid bulb at the end of diastolic period

end diastolic velocity of internal carotid artery 0 in cm/s

时间窗: initial time when patients are recruited

the velocity of internal carotid artery at the end of diastolic period

breath holding index 0 in percentage/seconds

时间窗: initial time when patients are recruited

breath holding index = (v2-v1)/v2\*100/t. v2 is average velocity of middle cerebral artery after breath holding, v1 is average velocity of middle cerebral artery before breath holding, t is time for breath holding.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ying Zhao

Director of the Department of Stomatology,Xuanwu Hospital

Xuanwu Hospital, Beijing

相似试验