The Effect of Varying Brightness Levels on Palpebral Aperture and the Point of Orbicularis Engagement Using EEG Signalling.
试验速览
- 阶段
- 不适用
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- The point at which the eyelid begins to contract under what brightness level
研究概览
简要总结
We aim to establish the point at which glare from bright lights begins to engage our eyelids - causing us to "squint". We will be using a video camera with an LED ring light around it facing the volunteer and we will record the eyelid position as the light brightness is increased gradually. Many studies have looked at the effect glare has on a person through qualitative questionnaires but few have been able to quantify this.
详细描述
Our study will aim to establish the point of orbicularis engagement based on luminous intensity Murray et al. created an Ocular Stress Monitor to see if the contracture of the muscles on the eyelid indicative of pain as a light source was increased in luminosity 8 Our study will go one step further by using video technology and a portable EEG machine to detect the pulses of lid contracture as luminosity of a ring light i s increased incrementally. An advanced calibrated datalogging LED light meter will simultaneously record the level of brightness to establish at which point the spike in EEG occurs. Screenshots from the video recording will be taken and accurate MRD1 measurements can be taken at the point of orbicular i s engagement.
The scientific justification for this research question is twofold We wish to establish the threshold at which orbicularis engages such that palpebral aperture and MRD measurements are altered. This is relevant to the technique of taking these measurements in the clinical environment and the light intensity at which these measurements are taken. We wish to establish the light intensity which should not be exceeded to take these measurements. As photography becomes increasingly used in oculoplastic s clinics we envisage palpebral aperture and MRD1 measurements being performed digitally rather than manually These measurements are relevant to pre operative and post operative imaging, and surgical planning. Furthermore, our results maybe applicable more widely to industry, for example vehicle headlights, bicycle lights, camera flash, workplace lighting.
Reference: Murray I, Plainis S, Carden D. The ocular stress monitor: a new device for measuring discomfort glare. Lighting Research Technology. 2002;34(3):231 239.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Aged between 18 and 65 years of age
- •A member of the Royal Free NHS trust
排除标准
- •No known ocular pathology
- •No lid problems/ptosis or previous lid surgery
- •No contact lenses in for duration of experiment
- •No pseudophakia
- •No neurological disease
研究组 & 干预措施
The observation of eyelid positioning and EEG pulses from the eyelid on increasing brightness
In a dimly lit room the participant will place their chin on the slit lamp We will use t he optimal background illumination used for Humphrey and Goldman visual fields which is 31.5 apostilbs (10Lux 9 They will look into the video camera placed 50cm away, which will have a dimmable remote control ring light fitted around it. The part icipant will have a reference measure taped to the headrest and three electrodes placed around the right eye. One active electrode place on the lower lid and one reference electrode towards the temporal margin and one earth electrode placed on the forehead The brightness of the ring light will be increased via the dimmer switch whilst simultaneously recording the lux with the LED light meter. The participant will be advised t o close their eyes if the brightness becomes uncomfortable and this will be repea ted three times.
干预措施: Review of eyelid positioning in increasing brightness levels (Other)
结局指标
主要结局
The point at which the eyelid begins to contract under what brightness level
时间窗: All carried out within a 2 week period
Using a light meter, ring light, and EEG machine
次要结局
未报告次要终点