Molecular Breast Imaging in Screening Breast Cancer

Chang Gung Memorial Hospital2 个研究点 分布在 1 个国家目标入组 164 人开始时间: 2015年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
164
试验地点
2
主要终点
Recall rate

研究概览

简要总结

The molecular breast imaging (MBI) is a potential modality to screen breast cancer. In this study, we compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and aim to determine best ways of breast cancer screening.

详细描述

Keywords: molecular breast imaging, MBI, breast cancer, mammography, sonography

  1. Background: In breast cancer screening, the sensitivity of mammography is about 71-96 %, but the sensitivity decreases in the three following groups: (1) under 50 years old; (2) dense breast parenchyma; (3) higher risk of breast cancer. The Health and Welfare Ministry data in recent 2 years showed Taiwanese women accepted mammography for screening in the ratio of only about 36%, representing many missed opportunities for early detection. One reason to reject mammography may be the discomfort caused by compression. To solve the above mammography possible weakness, other screening methods came into being, such as molecular breast imaging (MBI) of nuclear medicine. Radiotracer of Tc-99m sestamibi was found for targeting breast tumor 20 years ago, and approved by the FDA in 1997. However, the application is limited due to the suboptimal scanning camera design. Ten years later, the Mayo Clinics developed MBI technology, using small-sized semiconductor detectors. Then it become possible that the nuclear technologist have patient's breast tissue fit the detector in almost the same fashion of mammography without heavy compression.
  2. Objective: The aim of this study is to evaluate the recall rate and diagnostic accuracy of MBI, mammography and breast echo, for female population.
  3. Study design: Female patients referred to Nuclear Medicine Department for myocardial perfusion scan will be recruited in this study. It is because that MBI and myocardial perfusion scan share the same radiotracer. Then MBI will become additional scanning only. About 1800 female subjects will involve, and further mammography and/or breast sonography will be arranged within 6 months after MBI. Participants will be encouraged to receive mammography every 2 years and telephone survey. We hope that this study will help us to compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and to determine best ways of breast cancer screening.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Screening
盲法
None

入排标准

年龄范围
45 Years 至 69 Years(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • Female patients undergoing myocardial perfusion imaging will be eligible if they sign the informed consent.

排除标准

  • They are unable to understand and sign the consent form
  • They are physically unable to sit upright and still for 20 minutes.
  • They have undergone breast surgery or breast biopsy within the last 12 months.
  • They have had trauma to the breast tissue or undergone radiation treatment to the breast within the last 12 months.

结局指标

主要结局

Recall rate

时间窗: 6 months

The frequency with which a radiologist or physician interprets findings of an examination as positive

次要结局

  • Diagnostic efficacy(6 months)