The Effects of Joint Infection Following Arthroscopic Single-bundle ACL Reconstruction With Autologous Hamstring: a Retrospective Matched Cohort Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 104
- 试验地点
- 1
- 主要终点
- Graft signal intensity
研究概览
简要总结
This study was conducted to analyze the effect of joint infection on the bone tunnel, graft and articular cartilage following arthroscopic single-bundle anterior cruciate ligament (ACL) reconstruction with autologous hamstring, to summarize the features of MR findings after joint infection, and to correlate these findings with their possible factors.
详细描述
A retrospective matched cohort study was performed in 26 patients who underwent arthroscopic single-bundle ACL reconstruction with hamstring graft and developed postoperative joint infection in our institute from January 2002 to December 2017. They were matched 1:3 to patients who did not sustain joint infection after ACL reconstruction. MR scan was collected at the time of follow-up. Bone tunnel enlargement at tunnel aperture, midsection and exit of tibial and femoral tunnel was carefully assessed. Graft signal-to-noise quotient (SNQ) on MRI was calculated to evaluate graft maturity. Cartilage morphology was graded using Whole Organ Magnetic Resonance Imaging Score. A generalized linear mixed model was applied to analyze the effect of joint infection on the bone tunnel, graft and articular cartilage.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 16 Years 至 50 Years(Child, Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age between 16 to 50 years;
- •Underwent single-bundle ACL reconstruction with autologous hamstring;
- •Had valid follow-up magnetic resonance imaging (MRI) at least 1 year after surgery
排除标准
- •Concomitant ligament injury which need surgical repair;
- •Delayed onset of postoperative joint infection (>3 months after surgery).
结局指标
主要结局
Graft signal intensity
时间窗: 1 year after operation/infection
Proton Density weighted fat suppressed turbo-spin echo (PD-TSE-FS) sequence was taken to calculate the SNQof the graft. Graft signal intensity was measured at proximal, middle and distal end of the graft.
Tunnel enlargement
时间窗: 1 year after operation/infection
A 3.0T MRI unit (General Electric Healthcare) with an 8-channel coil was used for measurement. Anteroposterior and lateromedial diameter at tunnel aperture, midsection and exit of tibial and femoral tunnel (demonstrated as TTa, TTm, TTe, FTa, FTm, FTe) was measured on T1-weighted images (in millimeters)
Cartilage morphology
时间窗: 1 year after operation/infection
The cartilage morphology at surgery was assessed using Outerbridge classification for chondral lesion and recorded in operation note. cartilage morphology was assessed according to the Whole-organ magnetic scoring system (WORMS) of the knee on sagittal and axial T2-weighted FSE images.
次要结局
未报告次要终点
