Skip to main content
Clinical Trials/NCT05082337
NCT05082337
Completed
Not Applicable

The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures: A Feasibility Study

Institut universitaire de cardiologie et de pneumologie de Québec, University Laval2 sites in 1 country20 target enrollmentOctober 8, 2021

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Aortic Valve Disease
Sponsor
Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
Enrollment
20
Locations
2
Primary Endpoint
Presence of Major vascular complications
Status
Completed
Last Updated
4 years ago

Overview

Brief Summary

TAVR patients exhibiting post-procedural residual AR had higher mortality and hospitalization rates due to heart failure, with the extent of this association increasing proportionally to the severity of the regurgitation. Optimizing transcatheter valve performance by intra-procedural hemodynamic evaluation of AR and residual transvalvular gradient remains of high clinical importance.

Detailed Description

Continuous technological development and procedural refinements are important to further reduce TAVR peri-procedural complications, facilitate the minimalist strategy and improve clinical outcomes following TAVR. Residual aortic regurgitation (AR) has been one of the main drawbacks of TAVR. TAVR patients exhibiting post-procedural residual AR had higher mortality and hospitalization rates due to heart failure, with the extent of this association increasing proportionally to the severity of the regurgitation. Various actions could be undertaken to minimize AR and its consequences, either intraprocedural (balloon post-dilation, implantation of a second valve) or during follow-up (diuretic treatment, closest clinical follow-up or percutaneous leakage closure). Thus, an accurate diagnosis of the presence and severity of residual AR post-TAVR is key to implement the proper measures and optimize clinical outcomes. The use of cardiac imaging remains the gold standard for evaluating AR post-TAVR, limitations of contrast amount along with the subjectivity of AR evaluation by aortic angiography, and the challenges of echocardiography at the time of the TAVR procedure represent a significant drawback. Thus, alternative tools for evaluating the presence and severity of AR would be very helpful in this setting. Current data supports the implementation of hemodynamic measurements during TAVR procedures in order to improve the clinical decision-making process following valve implantation. However, these actions entail an inherent risk associated with the exchange of catheter-wires. The use of a support guidewire with pressure measurement capabilities would facilitate the hemodynamic evaluation of transcatheter valve performance in a safer and more rapid manner. The new SAVVY guidewire, with both dedicated pacing properties and allowing a continuous hemodynamic pressure monitoring during the procedure, is a unique system in the field and may represent an important step forward in the process of optimizing the TAVR procedure while facilitating procedural steps.

Registry
clinicaltrials.gov
Start Date
October 8, 2021
End Date
December 28, 2021
Last Updated
4 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
Responsible Party
Principal Investigator
Principal Investigator

Josep Rodes-Cabau

Principal investigator

Institut universitaire de cardiologie et de pneumologie de Québec, University Laval

Eligibility Criteria

Inclusion Criteria

  • Patients with severe symptomatic AS undergoing a TAVR procedure.

Exclusion Criteria

  • Failure to provide signed informed consent.
  • Extremely calcified aortic valve (Agatston score \>3000 AU)
  • Extremely horizontal aorta.
  • Severe septal hypertrophy (interventricular septum \>15 mm as measured by TTE).
  • Extreme tortuosity at the level of the iliofemoral arteries, thoracic or abdominal aorta.
  • Prohibitive surgical risk precluding (according to the Heart Team) conversion to open heart surgery in case of a life threatening complication.
  • Young patients (\<18 Years) and pregnant women

Outcomes

Primary Outcomes

Presence of Major vascular complications

Time Frame: Periprocedural

Major vascular complications related to the SAVVY guidewire are defined as stroke, bleeding or left ventricular perforation

Number of transcatheter valve malpositioning

Time Frame: Periprocedural

Pacing capture failure translating into valve malpositioning. Valve malpositiong will be evaluated by a landing site to low or too high, leading to hemodynamically unfavorable results.

Presence of Major complications

Time Frame: Periprocedural

Presence of major complications related to the SAVVY guidewire including (i) guidewire kink hindering or preventing the advancement of the transcatheter valve system

Number of valve embolization

Time Frame: Periprocedural

Pacing capture failure translating into valve embolization

Number of effective rapid pacing run

Time Frame: Periprocedural

Effective rapid pacing will be defined as an adequate ventricular pacing capture for a minimum of 10 seconds, with no capture loss, and leading to a reduction of aortic pressure of at least 50%, with/or a systolic pressure value \<60 mmHg. Efficacy will be assessed by the physician.

Number of accurate ventricular pressure

Time Frame: Periprocedural

Accurate ventricular pressure will be defines as a pressure wire measurements similar (differences \<5 mmHg) to those obtained simultaneously with a pigtail catheter in the same cavity or vascular segment (differences \<5 mmHg in SBP, differences \<5 mmHg in LVEDP).

Study Sites (2)

Loading locations...

Similar Trials