MedPath

Detecting Pulmonary Hypertension With the Eko CORE 500 Digital Stethoscope

Recruiting
Conditions
Pulmnary Hypertension
Registration Number
NCT07136623
Lead Sponsor
Eko Devices, Inc.
Brief Summary

This prospective, observational study will evaluate whether synchronized heart sound (phonocardiogram, PCG) and three-lead electrocardiogram (ECG) recordings (entered as separate interventions in PRS, though collected together in practice) collected with the Eko CORE 500 can help screen for pulmonary hypertension (PH). Adults (≥18 years) undergoing clinically indicated transthoracic echocardiography (TTE) and/or right heart catheterization (RHC) will complete one study visit (\~20 minutes). During the visit, study staff will obtain at least four 15-second CORE 500 recordings (aortic, pulmonic, tricuspid, and mitral areas). The clinical echocardiogram (and RHC, if performed) within ±7 days of the recordings will provide reference labels for the presence and severity of PH; de-identified demographic and clinical data may also be abstracted from the medical record.

The primary objective is to develop and validate a software algorithm to detect PH and, where possible, stratify severity using noninvasive PCG+ECG signals. These recordings are investigational data acquisitions for algorithm development only; they are not diagnostic procedures and will not be used for clinical decision-making. Primary performance measures are sensitivity and specificity versus echocardiogram and RHC references. No clinical decisions will be based on the investigational algorithm, and no changes to standard care are required. The study plans to enroll up to \~1,513 participants to obtain approximately 1,375 evaluable datasets across multiple outpatient sites.

Detailed Description

This is a prospective, observational, multi-site study to determine whether synchronized heart-sound (phonocardiogram; PCG) and three-lead electrocardiogram (ECG) recordings (entered as separate interventions in PRS, though collected together in practice) collected with the FDA (U.S. Food and Drug Administration)-cleared Eko CORE 500 digital stethoscope can assist in screening for pulmonary hypertension (PH). Adults (≥18 years) referred for clinically indicated transthoracic echocardiography (TTE) and/or right heart catheterization (RHC) will complete a single study visit (\~20 minutes). During the visit, trained staff will obtain at least four 15-second CORE 500 recordings from standard auscultation locations (aortic, pulmonic, tricuspid, and mitral).

The clinical TTE (and RHC, if performed) completed within ±7 days of the recordings will provide reference labels for the presence and severity of PH. If available, de-identified results from a clinical 12-lead ECG performed within 30 days of the TTE may also be abstracted for comparison. The primary objective is to develop and validate a software algorithm that detects PH from PCG+ECG signals; secondary objectives include assessing severity stratification and overall diagnostic performance (e.g., sensitivity/specificity, area under the receiver operating characteristic curve \[AUC\], positive predictive value \[PPV\], negative predictive value \[NPV\]), including subgroup analyses to evaluate generalizability. These recordings are investigational data acquisitions for algorithm development and detection research only; they are not diagnostic procedures and will not be used for clinical decision-making.

The study plans to enroll up to \~1,513 participants to obtain approximately 1,375 evaluable datasets (about 1,250 with TTE and 125 with RHC). No clinical decisions will be based on investigational algorithm outputs, and participation does not alter standard care. Key eligibility includes adults able to consent who have a clinical TTE or RHC within the protocol window; exclusions include current hospitalization and limited TTE studies. All study data are de-identified using site-maintained key-coded identification codes (IDs). PCG/ECG recordings are transmitted to a HIPAA (Health Insurance Portability and Accountability Act)-compliant, secure server; de-identified demographics, clinical data (e.g., TTE Doppler measures including TR \[tricuspid regurgitation\] velocity and estimated pulmonary artery systolic pressure, RHC hemodynamics), and relevant reports/images may be abstracted/uploaded per site procedures.

This minimal-risk study has IRB (Institutional Review Board) approval. No independent data monitoring committee is appointed; safety oversight is provided by site investigators with adverse event reporting per IRB policy. There is no cost to participants; modest compensation (≤$50, site-specific) may be provided. The CORE 500 hardware is FDA-cleared; however, the software algorithm evaluated in this study is investigational (not FDA-cleared). The aim is regulatory readiness for potential future submission without committing to a specific regulatory filing as part of this study.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
1513
Inclusion Criteria

Age ≥ 18 years.

Able and willing to provide informed consent.

Clinically indicated transthoracic echocardiogram (TTE) or right heart catheterization (RHC) scheduled/performed within ±7 days of the study recording visit.

Exclusion Criteria

Unwilling or unable to provide informed consent.

Currently hospitalized at the time of study procedures.

If enrolled via TTE path: limited (non-diagnostic) echocardiogram.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Area under the receiver operating characteristic (ROC) curve (AUC) for pulmonary hypertension (PH) detectionStudy completion (up to 12 months); reference within ±7 days.

Description: Area under the receiver operating characteristic (ROC) curve (AUC) of the phonocardiogram (PCG) + electrocardiogram (ECG) algorithm for classifying pulmonary hypertension (PH) vs. non-PH using probability outputs; reference is transthoracic echocardiography (TTE) and/or right heart catheterization (RHC) within ±7 days. 95% confidence intervals (CIs) reported.

Secondary Outcome Measures
NameTimeMethod
Positive and negative predictive values for PH detectionStudy completion (up to 12 months); reference within ±7 days.

Positive predictive value (PPV) and negative predictive value (NPV) at a prespecified operating point; reference is transthoracic echocardiography (TTE) and/or right heart catheterization (RHC) within ±7 days. 95% confidence intervals (CIs) reported.

Trial Locations

Locations (1)

University of California Los Angeles

🇺🇸

Los Angeles, California, United States

University of California Los Angeles
🇺🇸Los Angeles, California, United States
Lloyd Liang
Contact
1 (800) 900-UCLA
LLLiang@mednet.ucla.edu

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.