Surface Hardness and Wear Characteristics of Prefabricated and CAD/CAM Milled Artificial Teeth
- Conditions
- Surface Hardness and Wear Resistance of Artificial Teeth
- Interventions
- Other: surface hardness test for denture teethOther: wear resistance of denture teeth measurement
- Registration Number
- NCT06179615
- Lead Sponsor
- Mansoura University
- Brief Summary
Purpose: This study aimed to assess the 3-dimentional wear )3D) (volumetric loss) and 2-dimentional wear (2D) (vertical loss) and surface hardness of ready-made (prefabricated) and CAD/CAM milled artificial denture teeth.
material and methods: In a cross-over study design, ten completely edentulous patients were randomly chosen for this study and given two complete dentures. The first complete denture was constructed with pre-fabricated teeth. The second complete denture was constructed with CAD\\CAM milled teeth. The complete denture teeth were 3D scanned at the time of insertion (T0), after three months (T3), and after six months (T6) of denture insertion. Utilizing 3D surface superimposition techniques, the vertical (2D wear), and Volumatic (3D wear) material loss were measured. The hardness of the teeth were evaluated at the time of denture insertion (T0) then after 6 months (T6) of denture insertion by Vickers hardness test. Statistical analysis was done using SPSS software. Paired groups were compared by paired t test. Significant difference was considered if P ≤ 0.05.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 10
- completely edentulous
- angle class I maxillomandibular relations
- Angle's class II, III maxillomandibular relation
- systemic disease that affect the bone and soft tissue health
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description complete denture with CAD\CAM milled artificial teeth surface hardness test for denture teeth complete denture constructed with CAD\\CAM Milled artificial teeth and inserted in the patient mouth to be used for 3, 6 months complete denture with prefabricated artificial teeth wear resistance of denture teeth measurement complete denture constructed with prefabricated artificial teeth and inserted in the patient mouth to be used for 3, 6 months complete denture with CAD\CAM milled artificial teeth wear resistance of denture teeth measurement complete denture constructed with CAD\\CAM Milled artificial teeth and inserted in the patient mouth to be used for 3, 6 months complete denture with prefabricated artificial teeth surface hardness test for denture teeth complete denture constructed with prefabricated artificial teeth and inserted in the patient mouth to be used for 3, 6 months
- Primary Outcome Measures
Name Time Method wear resistance of denture artificial teeth 6 months after denture use 2D, 3D wear of denture teeth were measured using denture scanning and superimposition of the sanning at insertion to that after 3, 6 months using Exocad soft ware
surface hardness of the denture artificial teeth 6 months after denture use the measurement of surface hardness was done using Vickers's test. this measurements was done at insertion then after 6 months
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
faculty of dentistry, Mansoura univeristy
🇪🇬Mansoura, Egypt