Brief Summary

Purpose: This study aimed to assess the 3-dimentional wear )3D) (volumetric loss) and 2-dimentional wear (2D) (vertical loss) and surface hardness of ready-made (prefabricated) and CAD/CAM milled artificial denture teeth.

material and methods: In a cross-over study design, ten completely edentulous patients were randomly chosen for this study and given two complete dentures. The first complete denture was constructed with pre-fabricated teeth. The second complete denture was constructed with CAD\\CAM milled teeth. The complete denture teeth were 3D scanned at the time of insertion (T0), after three months (T3), and after six months (T6) of denture insertion. Utilizing 3D surface superimposition techniques, the vertical (2D wear), and Volumatic (3D wear) material loss were measured. The hardness of the teeth were evaluated at the time of denture insertion (T0) then after 6 months (T6) of denture insertion by Vickers hardness test. Statistical analysis was done using SPSS software. Paired groups were compared by paired t test. Significant difference was considered if P ≤ 0.05.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
10
Inclusion Criteria
  • completely edentulous
  • angle class I maxillomandibular relations
Exclusion Criteria
  • Angle's class II, III maxillomandibular relation
  • systemic disease that affect the bone and soft tissue health

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Arm && Interventions
GroupInterventionDescription
complete denture with CAD\CAM milled artificial teethsurface hardness test for denture teethcomplete denture constructed with CAD\\CAM Milled artificial teeth and inserted in the patient mouth to be used for 3, 6 months
complete denture with prefabricated artificial teethwear resistance of denture teeth measurementcomplete denture constructed with prefabricated artificial teeth and inserted in the patient mouth to be used for 3, 6 months
complete denture with CAD\CAM milled artificial teethwear resistance of denture teeth measurementcomplete denture constructed with CAD\\CAM Milled artificial teeth and inserted in the patient mouth to be used for 3, 6 months
complete denture with prefabricated artificial teethsurface hardness test for denture teethcomplete denture constructed with prefabricated artificial teeth and inserted in the patient mouth to be used for 3, 6 months
Primary Outcome Measures
NameTimeMethod
wear resistance of denture artificial teeth6 months after denture use

2D, 3D wear of denture teeth were measured using denture scanning and superimposition of the sanning at insertion to that after 3, 6 months using Exocad soft ware

surface hardness of the denture artificial teeth6 months after denture use

the measurement of surface hardness was done using Vickers's test. this measurements was done at insertion then after 6 months

Secondary Outcome Measures
NameTimeMethod

Trial Locations