Skip to main content
Clinical Trials/NCT04874376
NCT04874376CompletedNot Applicable

Clinical Study to Investigate Visual Performance, Contrast Sensitivity and Patient Satisfaction After Implantation of a Premium Monofocal Intraocular Lens

Beaver-Visitec International, Inc.6 sites in 1 country109 target enrollmentStarted: May 24, 2021Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
109
Locations
6
Primary Endpoint
monocular Best Corrected Distance Visual Acuity (CDVA) under photopic light conditions on the first implanted eye.

Study Overview

Brief Summary

Multicentric, retro- / prospective, open-label, observational PMCF study to investigate visual performance, contrast sensitivity and patient satisfaction after mono- or bilateral implantation of Isopure 1.2.3. intraocular lenses following cataract surgery.

The study treatment itself is not part of this observational clinical investigation. Only patients that already have been implanted with the device under investigation qualify for this retro- prospective observational clinical study.

Detailed Description

The study is a multicentric, retro- / prospective, open-label, observational PMCF study to investigate visual performance, contrast sensitivity and patient satisfaction after mono- or bilateral implantation of Isopure 1.2.3. intraocular lenses following cataract surgery.

The study treatment itself is not part of this observational clinical investigation. Only patients that already have been implanted with the device under investigation qualify for this retro- prospective observational clinical study.

Isopure 1.2.3. is CE approved and commercially available in the countries this clinical investgation is being carried out. The investigational device and all study products, including the devices used for the study examinations, will be used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient.

The study will be carried out in up to five clinical centers in Spain. The device under investigation (Isopure 1.2.3.) is a hydrophobic, glistening-free, acrylic Premium Monofocal intraocular lens (IOL) manufactured by the sponsor of this study, PhysIOL sa/nv.

Subjects participating in the trial will attend a total of maximum 1 study visit (from 120 days post-operative). This study visit will be minimum 20 days after the surgery of the 2nd eye. Subjects would have the option for unscheduled visits if required medically.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Treatment
Masking
None

Eligibility Criteria

Ages
45 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •• Male or female adults ages 45 years or older on the day of treatment that were mono- or bilaterally implanted with Isopure 1.2.
  • •intraocular lens minimum 120 days before the study visit;
  • •Maximum time between first and second eye treatment: 45 days (this accounts for bilateral implantations only);
  • •Capability to understand and sign an IRB approved informed consent form and privacy authorization;
  • •Clear intraocular media;
  • •Minimum set of retrospective preoperative and intraoperative data available as outlined in the examination matrix;
  • •Willing and able to conform to the study requirements.

Exclusion Criteria

  • •• Age of patient <45 years at the day of surgery;
  • •Time between first and second eye treatment: >45 days (this accounts for bilateral implantations only);
  • •Subjects who underwent previous intraocular or corneal surgery other than IOL implantation;
  • •Subjects with diagnosed degenerative visual disorders (e.g. AMD or CME);
  • •Subjects in whom in-the-bag implantation was not possible;
  • •Subjects in whom surgical complications occurred (e.g. posterior rupture).
  • •Subjects showing glaucoma;

Arms & Interventions

IOL retrospective data collection

Experimental

Experimental arm: Premium Monofocal intraocular lens.

Intervention: IOL implantation experimental (Isopure 1.2.3.) (Device)

Outcomes

Primary Outcomes

monocular Best Corrected Distance Visual Acuity (CDVA) under photopic light conditions on the first implanted eye.

Time Frame: From 120 days postoperative

No statistically significant difference between the monocular CDVA from 4 months follow up visit when compared to the parent IOL (Micropure 1.2.3). A significance level of 0.025 or lower (p \< 0.025) will be considered statistically significant. CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018.

Secondary Outcomes

No secondary outcomes reported