Use of the Smart Nitinol Stent System for the Treatment of Severe Atherosclerotic Carotid Stenosis: Study Protocol for a Retrospective, Non-randomized, Long-term Parallel Controlled Trial

Beijing Jishuitan Hospital0 个研究点目标入组 103 人开始时间: 2006年6月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
已完成
入组人数
103
主要终点
mRS score

研究概览

简要总结

To validate the long-term effects of implantation of the self-expanding Smart nitinol stent system for the treatment of severe atherosclerotic carotid stenosis in a 2-year follow-up study of a large patient cohort

详细描述

Atherosclerosis is a leading cause of carotid artery stenosis. The risk of atherosclerosis increases with age, occurring mainly in middle-aged and elderly populations. The morbidity and mortality of stroke caused by atherosclerosis also increase with aging. An epidemiologic study demonstrated that carotid artery intima-media thickness is a marker of atherosclerotic peripheral arterial disease, and found evidence that the likelihood of a clinical diagnosis of atherosclerosis increases two- to threefold from 20 to 90 years of age. The risk of atherosclerosis also increases with age in animals fed atherosclerosis-inducing diets. The close relationship between atherosclerosis and aging shows that atherosclerosis is a chronic and progressive degenerative disease.

Atherosclerotic carotid stenosis is an independent risk factor for ischemic cerebrovascular disease. Vascular stenting of carotid artery stenosis is an increasingly popular technique. It is safe, quick, minimally invasive, can be performed under local anesthesia, and can be used to treat proximal and intracranial lesions. Vascular stenting enables flow to be restored in previously narrowed vessels, restoring blood supply to the brain and preventing plaque rupture. Carotid artery stenosis of 70%-90% is considered the highest risk for stroke, and is a compelling indication for stenting. The Smart stent system (Cordis Corporation, Miami, FL, USA) is a nitinol self-expanding stent that is soft, elastic, has uniform radial tension and is readily endothelialized.

Phatouros et al. treated four patients with carotid artery stenosis >70% using self-expanding Smart stents and <20% residual stenosis was achieved in all cases; no transient ischemic attacks or new strokes occurred during a follow up period of 6 months. Drescher et al. also used self-expanding Smart stents in 13 patients with severe carotid artery stenosis and found no complications during a 6-month follow-up period. Wholey et al. deployed stents to treat carotid artery stenosis in more than 500 patients, and found that the rates of neurologic complications and restenosis were decreased after application of either balloon-mounted or self-expanding stents. Three-year follow-up results have shown that balloon-mounted stents lead to better vessel patency than self-expanding stents, but that balloon-mounted stents are vulnerable to compression. Lownie et al. examined the efficacy of self-expanding Smart stents in 21 patients with severe symptomatic carotid artery stenosis (stenosis >70%) without angioplasty. All patients were followed up for an average period of 19 months. Self-expanding Smart stents improved vascular stenosis and blood flow without the need for balloons or adjunctive protection devices.

Zhao et al. used Smart stents to treat patients with carotid artery stenosis of >65%, and found the treatment safe and effective, while observing no severe complications. Li et al. treated patients with carotid bifurcation and origin stenosis of >50% with self-expanding Smart stents, and found that patients' neurologic function improved to different extents, and that there were no strokes or transient cerebral ischemic attacks during a subsequent period of 13-14 months. Chen et al. used self-expanding Smart stents to treat 48 patients with carotid artery stenosis of 75%-99%, achieving favorable clinical outcomes in 43 (89.6%), with no recurrence of stenosis during a relatively short follow-up period of 1-6 months, and few postoperative complications or sequelae.

In a cohort of 38 patients with extracranial artery (internal carotid artery outer segment, vertebral artery or subclavian artery) stenosis treated with Smart stents and followed up for an average of 18 months, satisfactory clinical outcomes were achieved in 33 (86.8%). These investigators also treated another cohort of 41 patients with carotid artery stenosis with Smart stents, and concluded that vascular Smart stent deployment is an effective and safe method for treating carotid artery stenosis.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age >18 years
  • Of either sex
  • Carotid artery stenosis caused by atherosclerotic plaque
  • Diagnosed with severe atherosclerotic carotid stenosis according to a previously described method (North American Symptomatic Carotid Endarterectomy Trial Collaborators, 1991)
  • Severe carotid artery stenosis confirmed by transcranial Doppler and carotid duplex ultrasonography
  • Provision of informed consent regarding trial procedure

排除标准

  • Carotid artery stenosis caused by fibromuscular dysplasia, Takayasu's arteritis or radiation injury
  • Severe central nervous system disorders, such as complete loss of cerebral function on the affected side with cerebral paralysis
  • Life expectancy <2 years because of intracranial tumors or other diseases
  • Pregnant or lactating
  • Renal impairment (if use of contrast agent will worsen renal function)
  • Concurrent hemorrhagic disease, or contraindication to antiplatelet or anticoagulant therapies for safety reasons
  • Leakage of contrast agent indicative of vessel perforation
  • Dilated aneurysm proximal or distal to stenotic foci
  • Allergy to stent material
  • Complete occlusion of the carotid artery or lesion length >10 mm, accompanied by intravascular thrombus and multiple segments of stenosis confirmed by imaging examination
  • Intracranial hemorrhage within 3 weeks or large areas of cerebral infarction within 4 weeks of treatment
  • Unable to or declined to cooperate with follow-up examination
  • Unable to provide informed consent because of intellectual disability or language disorder

研究组 & 干预措施

Smart nitinol stent implantation group

Experimental

The Smart nitinol stent system was used (import product registration number YZB/USA 0115-2008; Nitinol stent system, trade name SMART Control). The stent system comprises a self-expanding stent and a delivery system. The self-expanding stent is composed of a nickel titanium alloy and the ends of the stent are equipped with tantalum radiopaque markers. The Smart nitinol stent system is sterilized with ethylene oxide gas and is intended for single use only.

干预措施: Smart nitinol stent implantation (Device)

Antiplatelet drug group

Active Comparator

Patients with carotid artery stenosis treated conservatively were commenced on an indefinite course of one or more oral antiplatelet drugs. The antiplatelet regimes comprised 100 mg or 300 mg aspirin before sleep with clopidogrel 125 mg or 250 mg daily; or 75 mg clopidogrel before sleep daily.

干预措施: antiplatelet drug (Drug)

结局指标

主要结局

mRS score

时间窗: 2 years after treatment

The mRS is a 7-point scale used to evaluate a patient's functional recovery.

次要结局

  • The recurrence of cerebrovascular events(1 and 2 years after treatment)
  • National Institute of Health stroke scale(NIHSS) score(1 and 2 years after treatment)