MedPath

Intra-abdominal Pressure Monitoring in Patients With Open Abdomen Undergoing Early Closure

Completed
Conditions
Open Wound of Other and Unspecified Parts of Abdomen
Interventions
Device: AbViser abdominal compartment pressure measuring device
Registration Number
NCT02107781
Lead Sponsor
Michigan State University
Brief Summary

The investigators will monitor the pressure generated inside the abdomen in a patient in whom the surgeon, for whatever reason, felt that the abdomen could not be closed at the initial operation. The investigators will aggressively treat rises in intra-abdominal pressure and see what changes, if any are found when the abdomen finally is closed.

Detailed Description

The detrimental effects of elevated intra-abdominal compartment pressure have been known for some time and are actively managed by most surgical critical care physicians. Similarly, it is well known that occasionally the abdomen cannot be immediately closed in some patients due to concern of elevated intra-abdominal pressure or ongoing contamination; these patients typically stay in hospital, often in expensive ICU's until final closure - and even then, some patients do not get definitive reconstruction of the abdominal wall until many months later, again adding to the expense of their care. Thus, there has been a move to give these patients early, aggressive closure of the abdomen, often using a combination of negative pressure wound therapy and biologic mesh. Currently these groups of patients who have early aggressive closure are incompletely studied; although abdominal compartment pressure measurements are routinely made on them, this is not commonly done intra-operatively when closure is being performed; nor have these patients been studied with continuous monitoring. This is especially striking considering the occlusive nature of negative wound therapy dressings: anecdotal increases in abdominal pressures have been noted in these patients, sometimes to dangerous levels. As there is accumulating evidence that diligent management of intra-abdominal pressure can improve outcomes in a variety of patients, there is an opportunity to apply accurate monitoring to a patient group that is also likely to benefit.

The investigators propose a prospective observational study on patients who are unable to be definitively closed at the time of surgery and are candidates for early aggressive abdominal closure. The investigators will monitor abdominal pressure using the AbViser continuous abdominal pressure monitoring device to ascertain whether there are episodes if intra-abdominal hypertension in these patients, and whether this improves or not after definitive closure. The research team will then attempt to correlate abdominal pressure measurements to outcomes. Finally the team will compare patients to historical controls using propensity scoring to explore differences in outcome.

Intra-abdominal pressure monitoring will be initiated when a patient has been identified as requiring an open abdomen. The monitoring will be done until the patient's abdominal wound has been closed and there are no elevated measurements. Once the patient has been discharged from the intensive care unit, the AbViser system will be discontinued. Patients will continue to be followed for the duration of their hospital stay and outcome measures will be assessed until discharge from the hospital, an expected average of 2 - 3 weeks.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
17
Inclusion Criteria
  • Postoperative Surgical Patients who have not undergone abdominal closure, irrespective of the type of dressing used to protect the viscera
Exclusion Criteria
  • Age less than 18 years
  • Coagulopathy
  • Moribund/not expected to survive 48 hrs
  • Patients in whom there is not a commitment to life supporting therapy
  • Patients who have had definitive closure at the time of operation
  • Patients in whom abdominal closure is not planned or not feasible

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Patients with open abdomenAbViser abdominal compartment pressure measuring devicePatients in a critical care unit with abdomen that was not closed during initial operation \& will have intra-abdominal pressure monitoring using the AbViser abdominal compartment pressure measuring device.
Primary Outcome Measures
NameTimeMethod
Intra-abdominal pressure (IAP) MeasurementsFrom the time when the patient has surgery & the abdomen is left open, immediately after abdomen is closed & until the patient's IAP system is discontinued, an expected average of 1 - 3 weeks.

The IAP will be recorded using the AbVisor system when abdomen is open, after surgical closure and will continue until the IAP system is discontinued

Secondary Outcome Measures
NameTimeMethod
Length of time in critical care unitFrom the time the patient is admitted to the critical care unit until discharged to a step-down unit. Measured immediately after discharge from critical care unit, an expected average of 1 - 3 weeks.

The length of time subjects require monitoring in a critical care unit.

Trial Locations

Locations (1)

Sparrow Health System

🇺🇸

Lansing, Michigan, United States

© Copyright 2025. All Rights Reserved by MedPath