A Randomized Controlled Trial Comparing a New State-of-the-art Non Ischemic Heart Preservation Method With the Standard Ischemic Cold Static Storage Method of Donor Hearts in Adult Heart Transplantation
试验速览
- 阶段
- 不适用
- 状态
- Enrolling By Invitation
- 发起方
- Region Skane
- 入组人数
- 66
- 试验地点
- 1
- 主要终点
- Survival free of acute cellular rejection and re-transplantation
研究概览
简要总结
The overall aim of this study is to compare a new state-of-the-art ex-vivo organ preservation method with standard ischemic cold static storage of donor hearts in adult cardiac transplantation.
Standard heart preservation before transplantation consists of cold ischemic storage of the heart. Clinical studies have shown that the morbidity and mortality risk increases with the extension of the allograft ischemic time over four hours. For each additional hour the mortality risk increase with 25% the first year. This time constraint is costly and results in severe logistical problems, leading to loss of transplantable organs. The preliminary results from our safety study, where six patients transplanted with the new state-of-the-art ex-vivo organ preservation method, have shown promising results.
The study is a multicenter, prospective, open, blinded endpoint, randomized, controlled clinical trial. The primary end-point is survival free of acute cellular rejection (ACR) and retransplantation within 1-year post-transplant. ACR will be assessed blinded. The secondary end-points are ischemia/reperfusion injury, early graft dysfunction, and QoL.
详细描述
SURVEY OF THE FIELD Ischemia and reperfusion (I/R) - elicited tissue injury contributes to morbidity and mortality. In organ transplantation, it is a major challenge. The imbalance in metabolic supply and demand within the ischemic organ results in tissue hypoxia and microvascular dysfunction. The following reperfusion enhances the activation of innate and adaptive immune responses resulting in a cell death program.
A damaged endothelium increases the risk of allograft rejection within 1-year after transplantation and a drug treated rejection increases the risk of chronicle rejection and five-year mortality. An improved preservation of the endothelium of the coronary arteries is therefore instrumental to achieve an improved short- and long-term outcome for the transplanted patients.
Standard heart preservation before transplantation consists of cold ischemic storage of the heart. Clinical studies have shown that the mortality risk increases sharply with extension of the allograft ischemic time over four hours. For each additional hour, the mortality risk increases with 25% the first year. Different myocardial cardioplegic preservation solutions and ex-vivo perfusion machines have been developed. Despite some promising experimental results, no consistent differences in outcome have been found. Our first-in-man pilot study, including 6 NIHP cases, show the device's feasibility and provide the first pieces of evidence that machines improves outcome of heart transplantation. However, as these results are based on a non-randomized study design with a few patients, a randomized study is needed to ensure the effect.
PURPOSE AND AIMS The purpose of this study is to compare a new state-of-the-art non ischemic heart preservation (NIHP) method, on heart allograft function, rejection episodes, and quality of life, with the standard ischemic cold static storage (SCS) method of donor hearts in adult heart transplantation.
STUDY DESIGN The study is a multicentre, prospective, randomized, open, blinded endpoint, controlled clinical trial. The study will randomly assign eligible patients to be transplanted with a donor heart preserved with either a new ex-vivo perfusion method (NIHP) or the standard cold static storage (SCS). The study will be performed at Skane University Hospital, Karolinska University Hospital, Linköping University Hospital, and Uppsala University Hospital, which cover two-thirds of the population in Sweden. Patients listed at these centres will be transplanted at Skane University Hospital and then returned to their centre for post-transplant care. The data collection, statistical analysis, and presentation of results will be done according to the CONSORT criteria. The main outcomes will be reported on intention to treat basis.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Other
- 盲法
- Single (Outcomes Assessor)
盲法说明
Acute cellular rejection assessment will be performed by a blinded access
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age ≥18 years
- •Signed informed consent form
- •Listed for heart transplantation
排除标准
- •Previous solid organ transplantation
- •Grown-up congenital heart disease (GUCH)
- •Kidney failure eGFR<40, calculated by CDK-EPI Creatinine, or ultrafiltration or dialysis or rapidly deteriorating kidney function due to a diagnosed renal disease
- •Coagulopathy due to known hepatic disease or heparin induced thrombocytopenia
- •Ongoing septicemia defined as positive blood culture (including with a durable VAD)
- •Incompatible blood group
- •Not able to understand the information provided during the informed consent procedure
- •Patients under pre-transplant desensitization protocol
- •Short term mechanical support pre-transplant (ECMO)
- •Patient diagnosed with Systemic Lupus Erythematous, sarcoidosis or amyloidosis
- •Combined organ transplantation candidates
- •Patient already consented for another transplant related intervention study
- •Inclusion criteria donor:
- •Age ≤70 years
- •Accepted as heart donor by the transplant team (research consent from the donor if required in country)
- •Exclusion criteria donor:
- •Previous sternotomy
- •DCD hearts
研究组 & 干预措施
Non-ischemic heart preservation (NIHP)
Non-ischemic hypothermic perfusion (NIHP): The donor heart is preserved using a portable heart-lung machine. The device perfuse the heart continuously with a a new preservation solution at a temperature of 8°C.
干预措施: Non-ischemic heart preservation (NIHP) (Device)
Standard cold storage (SCS)
Standard cold static storage (SCS): The donor heart is preserved using a standard crystalloid cardioplegia. The heart is in then storage i a transport box containing ice to keep the temperature around 4-8°C. The device does not perfuse the heart.
干预措施: Standard ischemic cold static storage (SCS) (Device)
结局指标
主要结局
Survival free of acute cellular rejection and re-transplantation
时间窗: One year
The primary end-point is defined as the difference between the two treatment arms in survival free of acute cellular rejection ≥1R and re-transplantation within one year. Acute cellular rejection assessment is based on post-transplant myocardial biopsy information and standard clinical evaluation.
次要结局
- Quality-of-life pre- and posttransplantation(One year)
- I/R-tissue injury(72 hours)
- Immediate graft dysfunction(24 hours)
- Intermediate graft function(21 ±7 days post transplantation)
- Chronicle graft rejection(One year post transplant (11- 15 months))
- Severe adverse events - Cardiac failure(30 days)
- Severe adverse events - Acute bleeding(30 days)
- Severe adverse events - Respiratory failure(30 days)
- Severe adverse events - Acute kidney failure(30 days)
- Severe adverse events - Permanent stroke(30 days)
- Severe adverse events - Permanent pacemaker(30 days)
