跳至主要内容
临床试验/NCT03073681
NCT03073681已完成不适用

Patient-Reported Satisfaction and Spectacle Independence With the ReSTOR 2.5 Combined With the ReSTOR 3.0 IOL in Cataract Surgery

MDbackline, LLC1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2017年3月3日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
100
试验地点
1
主要终点
Overall satisfaction with surgery

研究概览

简要总结

Patients implanted with the ReSTOR 2.5 multifocal IOL in the dominant eye and the ReSTOR 3.0 in the non-dominant eye have overall satisfaction and spectacle independence at least comparable to that with bilateral implantation of the 3.0 add lens. Glare and haloes and other unwanted visual side effects with this mixed combination of lenses is better than with bilateral 3.0 lenses.

详细描述

Patients desire spectacle independence for a range of distances, including distance, intermediate, and near. The ReSTOR 2.5 multifocal lens has been designed to allow better uncorrected intermediate vision and reduce glare and haloes compared to previous, higher-add models. However, their impact on overall patient satisfaction, glare & haloes (incidence and impact), and spectacle independence has not been examined with a patient-reported outcome study. Additionally, in clinical practice, many clinicians find that bilateral implantation of ReSTOR 2.5 yields insufficient near vision for about 30% of patients (1). For this reason, many surgeons prefer to implant the ReSTOR 2.5 in one eye (usually the dominant) and the ReSTOR 3.0 in the other eye.

MDbackline is a multi-center patient-reported research engine that has been in use since 2013 for data collection in several patient-reported outcome studies for major industry sponsors. Studies performed with MDbackline have been presented at major meetings and are in press with peer-reviewed journals. The investigators have previously conducted studies of patient satisfaction and spectacle independence with the higher add (3.0) multifocal lens prior to the approval of the ReSTOR 2.5. These data, which include about 85 patients, will be used as historical references. They showed a high degree of satisfaction and spectacle independence but complaints of glare and haloes in as many as 37% of patients ("a fair amount of glare" or more). (2) Since approval of the ReSTOR 2.5, the investigators have clinically observed far fewer complaints of glare/haloes when the lower-add lens is used in at least one eye.

In this study the investigators propose to evaluate patients with the ReSTOR 2.5 lens in one eye and the ReSTOR 3.0 in the other using substantially the same questionnaire in the previous study described above. The investigators plan to compare results of these new data (2.5/3.0 combination) with the previous study data (3.0/3.0).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients implanted with either a ReSTOR 2.5 or 3.0 multifocal within 24 months of the survey administration.
  • Patients with otherwise healthy eyes, not exhibiting any significant ocular morbidity that would be expected to influence outcome measures.

排除标准

  • Patients with visually significant co-morbidities (corneal, retina, optic nerve disease) that could affect their satisfaction with surgery
  • Patients with surgical complications either during or after surgery (capsule tears, iris trauma, decentered IOL, cystoid macular edema, etc.)
  • Patients with previous refractive surgery
  • Patients with ≥ grade 1 posterior capsule opacity at their last visit

结局指标

主要结局

Overall satisfaction with surgery

时间窗: at least 2 months after surgery

Overall satisfaction with surgery, defined as the percentage of patients who report "top box" (5 out of 5) satisfaction with implantation of a 2.5D add ReSTOR implant in the dominant eye and a 3.0D add ReSTOR implant in the non-dominant eye.

次要结局

未报告次要终点

研究者

发起方
MDbackline, LLC
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验