The Effect of Auricular Position on Measurement Values and Comfort in Measuring Body Temperature by Tympanic Method in Pediatric Patients

Istanbul University - Cerrahpasa2 个研究点 分布在 2 个国家目标入组 68 人开始时间: 2022年12月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
68
试验地点
2
主要终点
Level of comfort changes (by using Comfort Daisies) with or without positioning the auricula in pediatric patients.

研究概览

简要总结

The focus of the clinical research is to examine whether there is a difference in body temperature measurements with or without positioning the auricle in the measurements made with a tympanic membrane thermometer in pediatric patients aged 3-17, and to examine the effect of positioning the ear on comfort behaviors.

详细描述

It is the nurses' responsibility to monitor vital signs including body temperature, pulse, respiration and blood pressure. Ideal body temperature measurement; It should be a method that is reliable, easy, fast, low-cost, best showing the internal temperature of the body and least affected by environmental conditions. Measurement by the tympanic route; It is a method that is frequently preferred because it gives the correct value, measures the internal temperature, and is not affected by oral nutrition and fluid intake. While the measurement in a few seconds saves nurses time, it is also stated that it is more comfortable for patients than other thermometers.Tympanic membrane thermometers measure the temperature of the blood passing through the tympanic membrane in the ear with infrared radiation.If the tip of the thermometer cannot see the tympanic membrane (eardrum), erroneous results may occur. For this reason, the pinna position where the tip of the tympanic thermometer is placed is very important. It has been stated that in pediatric patients, due to the anatomical structure difference compared to adult patients, measurements should be made by placing them in a downward position. In studies conducted with children and newborns, there are different results in the evidence regarding the effect of auricular position on the measurement value. For this reason, this research is planned to determine the effect of auricular position on body temperature measurement values and comfort behaviors by using Visual Analogue Scale (VAS) and age-appropriate Comfort Daisies developed by Katharine Kolcaba in measurements made with a tympanic membrane thermometer in pediatric patients aged 3-17 years. With the results obtained from this study, it will be evaluated how the auricle position affects the measurement values and comfort behaviors in measuring body temperature by tympanic way in pediatric patients aged 3-17 years. It is thought that the results of this study will contribute to nursing practices and research.

Hypotheses:

H0: There is no significant difference between the body temperature measurement value, VAS score and comfort score performed without pulling the auricle, and the body temperature measurement value, VAS score and comfort score performed by pulling the auricle.

H1: There is a significant difference between the comfort behavior score in the measurement made without pulling the auricle and the comfort behavior score in the measurement made by pulling the auricle.

H2: There is a significant difference between the body temperature measurement value made without pulling the auricle and the body temperature measurement value made by pulling the auricle in patients.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
None

入排标准

年龄范围
3 Years 至 17 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Being between the ages of 3-17
  • Receiving inpatient care/treatment in the Pediatric Intensive Care Clinic
  • For the pediatric patient, the parents' willingness to participate in the study

排除标准

  • Being outside the age range of 3-17
  • Patient's medical condition;
  • Being sedated or unconscious,
  • Being intubated or tracheostomized,
  • Have had a head injury,
  • Have an ear disease, have an trauma/surgery,
  • Have an ear discharge, ear infection,
  • Have sepsis.
  • Implementation of interventions/treatments that will affect the measurement;
  • Application of treatment (drops) by ear,
  • Last antipyretic treatment taken before 4 hours,
  • Before and during body temperature measurement, interventions (hot and cold application, blood transfusion, hemodialysis and plasma exchange) that will affect the measurement

结局指标

主要结局

Level of comfort changes (by using Comfort Daisies) with or without positioning the auricula in pediatric patients.

时间窗: 2 minutes

We will use Comfort Daisies. Comfort Daisies has 4 daisies which include the expressions like "very good, sort of good, sort of bad and very bad".

Body temperature changes with or without positioning the auricula in pediatric patients.

时间窗: 2 minutes

We will measure the body temperature with tympanic thermometer and will use the Celcius as a measure of unit.

Level of comfort changes (by using Visual Analogue Scale) with or without positioning the auricula in pediatric patients.

时间窗: 2 minutes

We will use VAS (Visual Analogue Scale).Visual Analogue Scale is between 0 to 10.