"The Fingerprint: Spoke-wheel Sign" of Focal Nodular Hyperplasia: Assessment of Novel Ultrasound Approach Using Superb Microvascular Imaging Technique

Samsung Medical Center1 个研究点 分布在 1 个国家目标入组 62 人开始时间: 2016年5月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
已完成
入组人数
62
试验地点
1
主要终点
Grading of spoke-wheel sign on CEUS using sonazoid and SMI in patients with focal nodular hyperplasia

研究概览

简要总结

Focal nodular hyperplasia (FNH) in liver is the second common benign hepatic tumor. It usually shows hypervascular mass on imaging studies and it is not easy to differentiate with other hypervascular malignant tumor. For diagnosis of FNH, contrast-enhanced ultrasonography (US) has been used to detect 'spoke-wheel sign', which can be typically seen in FNH. However, temporal window of vascular phase using contrast-enhanced US (CEUS) is very short (about 10 sec) and coordination of patient's respiration during US exam is absolutely needed. Thus, the investigators will use Superb-Microvascular imaging (SMI, Toshiba, Japan) for detection of 'spoke-wheel sign' in patients with proven FNH, which enable to detect slow micro vascular flow without using CEUS.

First, to compare the detection rate of 'spoke-wheel sign' between CEUS using sonazoid (Perfluorobutane, GE healthcare) and SMI.

Second, to compare the accuracy of size measurement between gray-scale US and SMI (reference standard: CEUS using sonazoid.)

详细描述

  1. To evaluate the detection rate of 'spoke-wheel sign' on CEUS using sonazoid and SMI (primary outcome).

Each US findings during exam for patients with FNH were recorded by radiologist. The results were interpreted by consensus using 4 scale bar.

  1. Absence of 'spoke-wheel sign'
  2. Mild suspicious of 'spoke-wheel sign'
  3. Highly suspicious of 'spoke-wheel sign'
  4. Definite "spoke-wheel sign'
  5. To evaluated the accuracy of size measurement for FNH on gray-scale US and SMI (reference standard: CEUS using sonazoid).

To calculate the measurement error between each method and CEUS using sonazoid on US images using measurement of maximum diameter of tumor. 3. Sample size calculation according to the primary outcome.

Expecting the detection rate of "spoke-wheel sign" on SMI, 20% (known detection rate on CEUS using sonazoid, 23.5%), a sample size of 62 patients was required using 95% confidence interval.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
20 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with biopsy or imaging proven focal nodular hyperplasia

排除标准

  • Pregnant women
  • Patient's age > 70
  • Egg allergy
  • Breast-feeding women

研究组 & 干预措施

SMI and sonazoid (single arm)

Experimental

Patients with focal nodular hyperplasia will undergo ultrasonography with Superb-Microvascular imaging and additional sonazoid-enhanced ultrasonography. SMI is a software function in a Toshiba Aplio 500 system. Sonazoid is contrast-material for US and it is a intervention for patient with FNH. Sonazoid will be administered at a dose of 0.015 mL/kg by manual bolus injection, followed by a 10 mL normal saline flush via a peripheral venous line

干预措施: Sonazoid (Drug)

SMI and sonazoid (single arm)

Experimental

Patients with focal nodular hyperplasia will undergo ultrasonography with Superb-Microvascular imaging and additional sonazoid-enhanced ultrasonography. SMI is a software function in a Toshiba Aplio 500 system. Sonazoid is contrast-material for US and it is a intervention for patient with FNH. Sonazoid will be administered at a dose of 0.015 mL/kg by manual bolus injection, followed by a 10 mL normal saline flush via a peripheral venous line

干预措施: Superb-Microvascular imaging (Device)

结局指标

主要结局

Grading of spoke-wheel sign on CEUS using sonazoid and SMI in patients with focal nodular hyperplasia

时间窗: 1 day

a.To evaluate the detection rate of 'spoke-wheel sign' on CEUS using sonazoid and SMI (primary outcome). Each US findings during exam for patients with FNH were recorded by radiologist. The results were interpreted by consensus using 4 scale bar. 0. Absence of 'spoke-wheel sign' 1. Mild suspicious of 'spoke-wheel sign' 2. Highly suspicious of 'spoke-wheel sign' 3. Definite "spoke-wheel sign'

次要结局

  • Measurement error of focal nodular hyperplasia between b-mode US and SMI according to the reference standard, CEUS(1 day)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Woo Kyoung Jeong, MD

Associate professor

Samsung Medical Center