Assessment of Preoxygenation Strategies in the Prehospital Environment
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 30
- 试验地点
- 1
- 主要终点
- Fractional Expired Oxygen Concentration
研究概览
简要总结
Comparison of the preoxygenation efficacy of tidal volume breathing using three different preoxygenation techniques which are available to providers in the prehospital environment.
详细描述
Prospective randomised interventional study.
Healthy volunteers will be positioned supine and undergo preoxygenation by tidal volume breathing for 3 minutes using each technique in turn. The sequence of techniques for each volunteer will be randomised in advance. Investigators will be instructed to ensure a good mask seal throughout the testing period. At the end of a 3 minute preoxygenation period, after a brief breath hold, the volunteer will exhale into reservoir tubing, allowing the fractional expired oxygen concentration (FeO2) to be determined (primary outcome) using a calibrated gas analyser.
The techniques being assessed have been chosen from methods of preoxygenation commonly available to clinicians in the prehospital environment:
- Continuous Positive Airway Pressure mode with fractional inspired oxygen concentration (FiO2) 100% using a portable ventilator.
- Bag-valve-mask device (BVM) with 15 l/min oxygen flow.
- Non-rebreather mask (NRM) device with 15 l/min oxygen flow.
Volunteers will also be asked to indicate the subjective ease of breathing for each technique (secondary outcome) using a visual analogue scale (VAS).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Adult volunteers
排除标准
- •Pregnancy
- •Respiratory disease
- •Facial abnormality
- •Edentulous
研究组 & 干预措施
CPAP
3 minutes of preoxygenation with a portable ventilator providing Continuous Positive Airway Pressure (CPAP) at 5 cmH20 and an FiO2 of 100%.
干预措施: Continuous Positive Airway Pressure (CPAP) (Device)
BVM
3 minutes of preoxygenation with a bag-valve-mask (BVM) device and oxygen flow rate of 15 litres / minute.
干预措施: Bag-Valve-Mask (BVM) (Device)
NRM
3 minutes of preoxygenation with a non-rebreather mask (NRM) device and oxygen flow rate of 15 litres / minute.
干预措施: Non-rebreather Mask (NRM) (Device)
结局指标
主要结局
Fractional Expired Oxygen Concentration
时间窗: 3 minutes
Measure of denitrogenation efficacy
次要结局
- Ease of breathing assessment using a visual analogue scale(3 minutes)
研究者
Christopher Groombridge
Dr
Queen Mary University of London
