Randomized Clinical Trial of Tissue Ultrafiltration and Pressure Monitoring for the Diagnosis and Prevention of Compartment Syndrome
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 90
- 试验地点
- 26
- 主要终点
- To determine if use of Twin Star catheter with active fluid removal reduces muscle compartment pressure vs Twin Star catheter without fluid removal by comparing the randomized groups. Success will be defined by a p-value less than 0.05 (two-sided).
研究概览
简要总结
An investigation of a new catheter and pressure monitor system that may help to prevent a complication called compartment syndrome from developing in an injured leg. Compartment syndrome occurs when too much fluid builds up in the muscles of the injured leg. This causes a lot of swelling and increases pressures within the leg that can cause permanent damage muscles and nerves in the leg.
详细描述
Compartment Syndrome (CS) may occur in patients with a fracture or crushing injury to an extremity. The current standard-of-care for patients at risk of developing CS is clinical by watching for signs and symptoms of CS, and if needed, measuring the pressure within the muscle compartment (intramuscular pressure, IMP). Currently, IMP measurements are made by placing a percutaneous pressure sensor into the targeted muscle compartment, which is then attached to a pressure monitor. Whenever the clinical exam and/or pressure measurements suggest that CS is developing, fasciotomy is generally performed immediately.
Twin Star Medical has developed a novel Compartment Monitoring System (CMS) that consists of a pressure monitoring module and two types of catheters. Both Twin Star Catheters remove interstitial tissue fluid, which may contribute to a reduction in compartment pressure, and which may be used for clinical analysis to determine if certain analyte indicators of muscle injury (biomarkers) can be predictive of CS development. One type of catheter Pressure Measurement/Fluid Collection, (PMFC), removes fluid and monitors pressure via a solid-state fiber optic transducer at the tip of the catheter. The other type of catheter, Fluid Collection (FC), only removes fluid and does not have a pressure transducer at the tip. The monitoring module senses, displays and records pressure as measured by the PMFC catheter as well as provides a vacuum source, which is required for the operation of the fluid removal catheter. The Twin Star CMS Monitoring Module has been successfully tested to (1) ensure the delivery of the specified functional performance requirements needed to reliably operate the Twin Star Catheter, and (2) meet current electrical safety standards established for clinical use. The first model of the Twin Star catheter and monitor was reviewed and approved by the Food and Drug Administration (FDA) for the indications of pressure measurement and the withdrawal of interstitial fluid. The devices being used for this clinical study represent the newly designed catheter and monitor and are not FDA approved and are therefore considered investigational. It is anticipated that the second-generation model of the catheter and monitor will be submitted to the FDA for approval while this study is being conducted.
The purpose of this Study is to determine if the removal of interstitial fluid by the Twin Star Catheter can lower muscle compartment pressure and impact other measures of subject clinical status, including possible reduction of the need for fasciotomy. The Study population will be Subjects who have suffered an isolated tibial fracture (open or closed) requiring surgical stabilization within 72 hours of injury. This Study will use an Adaptive study design in which a total of up to 90 subjects will be enrolled. All Subjects will receive the Twin Star catheters, which will be inserted at the end of the surgical procedure to stabilize the tibia fracture and will be connected to the pressure monitor before leaving the surgical room. The catheters will be used for the first 24-hours after surgical fixation of the affected lower leg in order to (1) measure and record muscle compartment pressure, and (2) remove accumulated interstitial fluid in the subset of subjects that are randomized to the Treatment Group. The first 20 Subjects (Phase 1) will not be randomized; all will be actively treated but with different combinations of catheters and vacuum levels. The purpose of Phase I of the study is to optimize treatment parameters that will be used in the remaining 70 subjects, which will constitute Phase II. All subjects will receive a total of 3 catheters placed in the anterior compartment. Subjects in Phase 1 will be enrolled into two groups: 1) receiving constant vacuum (-150 mmHg) and fluid removal or, 2) receiving intermittent vacuum (-50 mmHg) and fluid removal. Within the anterior compartment, there will be one PMFC and 2 FC catheters inserted.
The first 10 subjects in Phase 1 will all be treated with single-fiber catheters, but with one of two different vacuum levels (intermittent at -50 mmHg or constant at -150 mmHg). After the first 10 subjects have completed the study, fluid removal results will be analyzed. If results demonstrate that fluid in the anterior compartment is being withdrawn at a rate of ≥ 0.5 mls/24 hours, the second group of 10 subjects will continue using the same single fiber catheters. If the results of the first 10 subjects demonstrate fluid is being withdrawn in the anterior compartment at < 0.5 mls/24 hours, the next 10 subjects will instead receive treatment with two multi-fiber FC catheters plus the same PMFC catheter.
After the first 20 subjects have been enrolled in the study, the remaining subjects to be enrolled in Phase 2 will be randomized to either a Treatment or Control group. Both groups will receive treatment with whichever combination of catheter type (single or multi-fiber) and vacuum (constant or intermittent) was most efficacious in terms of fluid removal in Phase 1. The randomization will determine whether subjects will receive no vacuum at all (Control Group: Monitoring alone) or the fluid removal mode that was shown to be best in the first phase of the study (Treatment Group: Monitoring plus Fluid Removal).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Prevention
- 盲法
- Quadruple (Participant, Care Provider, Investigator, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 60 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Subject with a tibial shaft fracture requiring intramedullary nailing or bicondylar tibial plateau fracture requiring application of a knee-spanning external fixator.
- •Operative procedure (nailing or external fixation) performed within 72 hours of injury.
- •The Subject is between 18 and 60 years of age.
- •Able to understand what he/she is being asked to do, willing/able to understand and sign the Informed Consent to return for follow-up visits at 2 weeks and 3 months post surgery.
排除标准
- •Current evidence of CS prior to Study.
- •Surgical stabilization will result in the presence of a bead pouch or wound vac or other dressing that would interfere with placement of any of the three Catheters in the anterior compartment.
- •The Subject has a medical condition(s) that precludes use of Catheters, such as dermatologic conditions, immunological deficits or traumatic skin lesions that interfere with Catheter placement.
- •The Subject has co-morbidities that may place the Subject at risk of hypotension (e.g., significant blood loss, heart failure, significant chest or abdominal trauma, septicemia, pelvic fractures, femur fractures or massive soft tissue trauma.)
- •Likely problems, in the investigator's judgment, with maintaining follow-up (including developmental delay, address greater than 2 hours drive from the treating institution, substance abuse problems, intoxication, current or pending incarceration, etc.).
结局指标
主要结局
To determine if use of Twin Star catheter with active fluid removal reduces muscle compartment pressure vs Twin Star catheter without fluid removal by comparing the randomized groups. Success will be defined by a p-value less than 0.05 (two-sided).
时间窗: fluid removal will be collected & recorded at 2, 4, 8, 16, & 24 hrs after catether insertion.
次要结局
- Compares the treatment and control groups on change in perfusion pressure (defined as diastolic blood pressure minus IMP) over time. The randomized groups will be compared with a two-sided p-value less than 0.05 defining success.(Perfusion pressure will be collected and recorded at 2, 4, 8, 16 & 24 hrs post-catheter insertion)