Origin to Insertion Kinesio Tapping vs Non-Directional Kinesio Tapping on Quadriceps Peak Torque
- Conditions
- Quadriceps Muscle Atrophy
- Interventions
- Other: placeboOther: Cura Kensio-tapping
- Registration Number
- NCT05768022
- Lead Sponsor
- University of Jazan
- Brief Summary
This study was conducted to investigate the effect of kinesio tapping on electrical activity and peak torque of quadriceps during concentric and eccentric muscle contraction were carried out in the motion analysis Laboratory.
- Detailed Description
A Pretest posttest control group design was used to. Two hundred normal subjects of both sexes were recruited.
Subjects were randomly assigned into two groups of equal number.
* Cura Kensio-tapping group: consisted of 100 subjects (females and males) will receive kinesio taping from origin to insertion on the superficial muscles of Quadriceps femoris (vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF).
* Placebo-Group: consisted of 100 subjects (females and males) will receive placebo kinesio taping across quadriceps.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 200
- Age must be ranged from 22-30 years.
- Body mass index must be ranged from 20-24.9 kg/m².
- Knee or quadriceps disorders preventing physical stress.
- Cardiovascular or neurological problems.
- Athletic subjects.
- Smokers.
- Heavy caffeine intake subjects.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Placebo placebo 100 subjects (females and males) will receive placebo kinesio-taping across quadriceps. Cura kinesio-taping Cura Kensio-tapping 100 subjects (females and males) will receive kinesio taping from origin to insertion on the superficial muscles of Quadriceps femoris (VM,VL, RF).
- Primary Outcome Measures
Name Time Method Peak Torque Measurement 2 After the application of tapping by 10 minutes The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.
Peak Torque Measurement 3 24 hours after tapping. The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.
Peak Torque Measurement 4 72 hours After tapping The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.
Peak Torque Measurement 1 Before tapping. The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.
Peak Torque Measurement 5 5 days after removal of tapping b The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Jazan University
🇸🇦Jazan, Gizan, Saudi Arabia