MedPath

Origin to Insertion Kinesio Tapping vs Non-Directional Kinesio Tapping on Quadriceps Peak Torque

Not Applicable
Completed
Conditions
Quadriceps Muscle Atrophy
Interventions
Other: placebo
Other: Cura Kensio-tapping
Registration Number
NCT05768022
Lead Sponsor
University of Jazan
Brief Summary

This study was conducted to investigate the effect of kinesio tapping on electrical activity and peak torque of quadriceps during concentric and eccentric muscle contraction were carried out in the motion analysis Laboratory.

Detailed Description

A Pretest posttest control group design was used to. Two hundred normal subjects of both sexes were recruited.

Subjects were randomly assigned into two groups of equal number.

* Cura Kensio-tapping group: consisted of 100 subjects (females and males) will receive kinesio taping from origin to insertion on the superficial muscles of Quadriceps femoris (vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF).

* Placebo-Group: consisted of 100 subjects (females and males) will receive placebo kinesio taping across quadriceps.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
200
Inclusion Criteria
  • Age must be ranged from 22-30 years.
  • Body mass index must be ranged from 20-24.9 kg/m².
Exclusion Criteria
  • Knee or quadriceps disorders preventing physical stress.
  • Cardiovascular or neurological problems.
  • Athletic subjects.
  • Smokers.
  • Heavy caffeine intake subjects.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Placeboplacebo100 subjects (females and males) will receive placebo kinesio-taping across quadriceps.
Cura kinesio-tapingCura Kensio-tapping100 subjects (females and males) will receive kinesio taping from origin to insertion on the superficial muscles of Quadriceps femoris (VM,VL, RF).
Primary Outcome Measures
NameTimeMethod
Peak Torque Measurement 2After the application of tapping by 10 minutes

The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.

Peak Torque Measurement 324 hours after tapping.

The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.

Peak Torque Measurement 472 hours After tapping

The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.

Peak Torque Measurement 1Before tapping.

The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.

Peak Torque Measurement 55 days after removal of tapping b

The peak torque of quadriceps muscle of dominant lower limb was measured using Biodex system 830-200 Isokinetic dynamometer.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Jazan University

🇸🇦

Jazan, Gizan, Saudi Arabia

© Copyright 2025. All Rights Reserved by MedPath