主要终点
Hemostasis within 15 minutes

研究概览

简要总结

The InSeal vascular closure device (VCD) is assessed as percutaneous closure of artery access sites for quick hemostasis and ambulation in patients who have undergone large bore endovascular catheterization procedures.

The study hypothesis is that the VCD is safe and efficient in achieving hemostasis in the study population.

详细描述

The increasing variety of arterial devices having a large crossing profile requiring the use of a large bore sheath is mandating focus on large bore closure. Such procedures include endovascular abdominal repair (EVAR), thoracic (TEVAR) aortic repairs and transcatheter aortic valve implantation (TAVI) typically involve sheaths and delivery catheters with 14-25Fr profiles.

Today, the typical closing technique (labeled in Europe) for such large sheath size is a one where sutures are deployed prior to the insertion of the large sheath with the sutures tied at the end of the procedure. This technique is cumbersome, hard to learn, complex to use and has relative high complications and failure rate.

The InSeal VCD device model 13-517, is easy to use, fast, affords immediate reliable hemostasis, and supports a wide range of sheath punctures size and artery's dia. 6-10 mm, while leaving a minimal amount material behind and will not limit re-access.

While each of these features may be found in one commercial device or another, to date there is no single device that meets all the market requirements.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Candidate for large bore catheterization procedure (such as TAVI, aortic endograft repair) using a CE approved 18Fr access sheath.
  • Femoral, axillary or subclavian artery diameter at sheath insertion site is between 5.5-10mm
  • Subject age is at least 18 years
  • Patient has signed most recent approved version of the Informed Consent
  • Existence of an additional arterial access port is required in instances where an occluding balloon is planned to be used as a safety precaution.

排除标准

  • Women Of Child Bearing Potential (WOCBP)
  • Legally non-competent patients
  • Patient participating in another clinical study at the time of the InSeal VCD study
  • Sheath insertion point is less than 12mm proximal to a bifurcation having a diameter greater than 2.5mm
  • Side branch of greater than 2.5mm in diameter less than 4cm proximal to the puncture site.
  • Known severe allergy to metal and membrane material
  • Prior target artery closure with a vascular closure device having intravascular component (such as Angio-Seal) 30 days prior to catheterization
  • Subjects with known coagulopathy, preexisting hematoma, arteriovenous fistula, or pseudoaneurysm at the vessel access site prior to artery closure
  • Patients that do not tolerate aspirin and clopidogrel anticoagulation treatment
  • Prior vascular surgery or vascular graft in region of access site
  • Significant calcification, atherosclerotic disease, or stent within 1.5 cm of the puncture site that may interfere with the operation of the experimental device

结局指标

主要结局

Hemostasis within 15 minutes

时间窗: 15 minutes

Hemostasis within 15 minutes following vessel access site closure and after ACT falls below 200 seconds. Measured by operator using standard time measuring device (e.g., stopwatch)

次要结局

  • Combined rate of closure-device related major adverse events(1 month)

研究者

发起方
InSeal Medical Ltd.
申办方类型
Industry
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验