MedPath

Ultrasound Guided Bilateral Erector Spinae Plane Block Versus Tumescent Anesthesia

Not Applicable
Completed
Conditions
Breast Hypertrophy
Pain, Postoperative
Interventions
Procedure: Tumescent Anesthesia
Procedure: Erector Spinae Plane Block
Registration Number
NCT03558880
Lead Sponsor
Kahramanmaras Sutcu Imam University
Brief Summary

In breast reduction surgery, pain control is usually performed with tumescent anesthesia, thoracic epidural anesthesia, intercostal nerve blocks and paravertebral block applications. Tumescent anesthesia is also preferred by plastic surgeons because of the varying risk of thoracic epidural anesthesia and paravertebral block applications.

After the Erector spinae block was first described by Forero in 2016, it was reported to have been applied in many cases, including breast surgery.

It is considered to be a safer block because of the presence of paravertebral block-like activity and the location where the needle is guided away from the pleura. The investigators aimed to compare postoperative analgesia consumption, pain scores and patient satisfaction of erector spine block with tumescent anesthesia in patients who underwent reduction mammoplasty operation under general anesthesia in this double-blind prospective randomized study.

Detailed Description

Patients aged 18-65 years undergoing bilateral reduction mammoplasty. Patients were randomly divided into two groups with closed envelope to perform tumescent anesthesia and erector spinae block.

All patients were premedicated with oral midazolam 0.5 mg/ kg preoperatively. All patients received standard general anesthesia protocol as induction with 2-3 mg/kg iv propofol and 1-1.5 mcg/kg fentanyl and 0.6 mg/kg iv rocuronium. Endotracheal intubations were performed 7.0 or 7.5 endotracheal tubes with the patient in a supine position. Anesthesia maintenance was with sevoflurane 0.5/kg/mg remifentanil infusion and in a 50% O2 -50% air mixture. Standard monitoring of the patients included of heart rate, invasive systolic, diastolic and mean blood pressure and peripheral oxygen saturation and the operating times were recorded.

At approximately 30 minutes before the end of surgery, 8mg dexketoprofen IV was administered to all patients. At the end of the operation, all the patients were performed with iv PCA(Patient Controlled Analgesia).

Demographic data such as age, weight, and height of the patients were recorded. After patients informed about pain score NRS (Numeric Pain Rating Scale) and patient satisfaction score ( one to ten) recorded by the nurse of PACU and ward.

Recruitment & Eligibility

Status
COMPLETED
Sex
Female
Target Recruitment
44
Inclusion Criteria

The American Society of Anesthesiologists physical status classification I-III undergoing reduction mammoplasty

Exclusion Criteria

History of allergic reactions to local anesthetics Rash or infection at the injection site Anatomical abnormality Bleeding diatheses Coagulopathy liver diseases

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Tumescent AnesthesiaTumescent AnesthesiaAfter the general anesthesia was given, 1 mL of 0.1% adrenaline (1/1000) and as 20 mL of 0.5% bupivacaine solution of tumescent in a total of 1000 mL Ringer's lactate applied by the surgeon applied equally to both breasts
Erector Spinae Plane BlockErector Spinae Plane BlockBefore the general anesthesia Erector Spinae Plane Block was performed.
Primary Outcome Measures
NameTimeMethod
Use of analgesic consumptions24 hour

Total tramadol consumptions with patient controlled device

Secondary Outcome Measures
NameTimeMethod
Numeric Pain Rating Scale30 minute, 1,2,4,6,12,24 hour

The 11-point numeric scale ranges from '0' representing one pain extreme (e.g. "no pain") to '10' representing the other pain extreme (e.g. "pain as bad as you can imagine" or "worst pain imaginable").

Trial Locations

Locations (1)

Kahramanmaras Sutcu Imam University Hospital

🇹🇷

Kahramanmaras, Turkey

© Copyright 2025. All Rights Reserved by MedPath