Skip to main content
Clinical Trials/NCT02680028
NCT02680028
Completed
Not Applicable

Randomised Trial of Trochanteric Hip Fractures Treated With Either a Short or Standard Length Intramedullary Nail

Peterborough and Stamford Hospitals NHS Foundation Trust1 site in 1 country229 target enrollmentNovember 2015
ConditionsHip Fracture

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Hip Fracture
Sponsor
Peterborough and Stamford Hospitals NHS Foundation Trust
Enrollment
229
Locations
1
Primary Endpoint
Regain of mobility as assessed by a mobility score
Status
Completed
Last Updated
5 years ago

Overview

Brief Summary

In England each year over 65,000 people fracture their hip. Most of these patients are elderly females with the fracture occurring after a simple trip or stumble. Approximately half of these fractures are classified from their relationship to the hip joint capsule as extracapsular. The majority of these fractures are treated surgically by internal fixation using, either a plate and screws (sliding hip screw) or nail and screws (intramedullary nail).

Recent randomised studies from Peterborough involving 1000 patients have indicated that there are modest benefits for treating this type of fracture with an intramedullary nail in comparison to a sliding hip screw. This study aims to progress from these earlier studies to determine if a slightly thinner and shorter intramedullary nail (175mm in length), has any significant advantages or disadvantages to the standard length (220mm) intramedullary nail.

Both implants to be used in this study are in routine use around the world and are being used within their licenced indication. The study is therefore using two different designs of implant within their recommended area of use, but in which there is uncertainty as to which is the best design.

Detailed Description

The trial will be run as close to the ideal trial methodology for a randomised trial as specified by the CONSORT statement as possible. This will include secure randomisation, intention to treat analysis, full reporting of outcomes and clinical follow-up by a person who is blinded to the prosthesis used. The trial will follow the code of good clinical practice as specified by the hospital trusts Research and Development Committee. In Peterborough all hip fracture patients are admitted to the acute trauma ward and transferred to the care of the Chief Investigator (Mr Martyn Parker (MJP)). Those patients that are willing to participant in this randomised trial are consented prior to surgery. Treatment follows standard evidence based protocols with follow-up of all patients in a hip fracture clinic. A comprehensive database is maintained for all patients containing both audit and research data. Included in this is a standardised assessment of outcome.

Registry
clinicaltrials.gov
Start Date
November 2015
End Date
June 2019
Last Updated
5 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Sponsor
Peterborough and Stamford Hospitals NHS Foundation Trust
Responsible Party
Principal Investigator
Principal Investigator

Martyn J Parker

Consultant Orthopaedic Surgeon

Peterborough and Stamford Hospitals NHS Foundation Trust

Eligibility Criteria

Inclusion Criteria

  • All patients admitted to Peterborough City Hospital with a trochanteric hip fracture (type A1 type A2) that is to be treated by internal fixation with an intramedullary nail.

Exclusion Criteria

  • Patients who decline to participate or in whom consent or assent is not available
  • Patients admitted when MJP is not available to supervise treatment
  • Patients with pathological fractures from Paget's disease of bone secondaries from tumour
  • Patients with a Subtrochanteric fracture and those of the reversed and transverse fracture type (A3 fractures)

Outcomes

Primary Outcomes

Regain of mobility as assessed by a mobility score

Time Frame: 1 year

Parker MJ, Palmer CR. A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg Br. 1993;75:797-8. Validation Kristensen MT, Bandholm T, Foss NB, Ekdahl C, Kehlet H. High inter-tester reliability of the new mobility score in patients with hip fracture. J Rehabil Med 2008;40:589-91. Mobility will be assessed using a scale of 0 to 9. Nine represents full mobility indoors and outdoors without walking aids; Zero represents a bed-bound patient.